3m x 45cm Arrived Tower Section, Galvanized by Immersion, Up to 60 m Elevation. Wetlands.

Skip to product information
1 of 1
  • Cumple norma ISO 9001:2015 para alta calidad
  • Carga máxima de 500 kg, estructura robusta
  • Resistencia al viento hasta 200 km/h
  • Galvanizado en caliente para protección anticorrosiva
  • Altura máxima 60 m con tramos prefabricados

54 in stock

Modelo: STZ-45G

Proveedor: SYSCOM TOWERS

Código SAT: 43222903

Tax included. Shipping calculated at checkout.
Our Commitment ×
By purchasing this product you are making a positive impact. We contribute of each sale and we’ve partnered with WeAreGoodness.io
View full details

Highlights:
  • Product manufactured under standard: ISO 9001:2015.
  • Each section is manufactured by numerical control machinery.
  • Includes hardware for installation.
  • Recommended for humid areas or in environments with moderate corrosion.
  • According to the hot dip galvanizing standard NMX-H-004-SCFI-2008, ASTM A-123 and ISO-1461.
Physical Characteristics:
  • Maximum Load: 500 Kg.
  • Maximum height: 60 m. (20 sections)
  • Wind Resistance: 200 Km/hr.
  • Material: Tubo industrial 1 1/4" (Cal.14).
  • Semiflecha (Zig-zag): Redondo 3/8".
  • Nipple: 12 cm.
  • Face width: 45 cm.
  • Weight: 27.5 Kg.
  • Dimensions: 3 m length
  • Frame material: Steel (A-36).
  • Anti-corrosion protection: Hot dip galvanizing (NMX-H-004-SCFI-2008)
Application:
  • Point-to-Point Systems.
  • Point - Multipoint System.
  • Cellular signal amplification.
  • Lightning rod systems.
  • Repeating base radios.
  • Monitoring points.
  • Iluminación.
  • Emergency audible signaling.
  • And more.

Highlighted technical notes:

  • Make sure the installation is performed by a trained professional.
  • Schedule a maintenance plan to check tension on retainers and tighten bolts.
  • Do not install solar panels higher than 6 meters. Check compatibility between solar cells and mounts.
  • A stress study must be performed when placing an eccentric load on a tower. This can cause excessive torsion and bending in the tower causing structural failures.
  • The declared weight is for the equipment without accessories and without packaging.
  • The towers can be purchased in complete kits. SEE TOWER KITS.

Warning:

  • Hot dip galvanizing is recommended for humid areas, salty and/or corrosive environments, industrial parks with gas release (SEE MAP OF AREAS).
  • The tower must be painted according to (at least) CFE specification D8500-02 (7 symmetrical stripes of orange and white colors alternating, starting and ending in orange.
  • It must include night lighting, at least two lights, one in the middle and another at the top.
  • Local regulations should be consulted according to the municipality to ensure a correct and legal tower installation.
  • We recommend at all times following the recommendations for retaining installation: SEE RETAINER INSTALLATION DIAGRAM.