Vibration Meter with Fluke Connect

The reliable way, repeatable and accurate to check bearings and machine condition
Make maintenance decisions with confidence. The Fluke 805 FC Vibration Meter is the most reliable vibration detection device available for frontline mechanical troubleshooting teams who need repeatable readings and severity escalations of overall vibration. the condition of the bearings and the condition of the machine.
Manage and monitor workflow for better maintenance results
With the Fluke Connect mobile app, It's now easier than ever to manage your vibration detection workflow. Integrated machine profile functionality allows you to set up machine profiles using the app and then send them directly to your 805 FC vibration meter. Then, Users can use the list of machine profiles to create work orders and develop route-based maintenance schedules that can be dynamically sent to technicians in the field, helping ensure proper focus on critical assets. Once a machine is tested, The 805 FC communicates the results directly to the application and associates them with the appropriate profile and route. This data can be easily shared between teams, so you can make better maintenance decisions.
Other useful features:
- Reliable device, repeatable and accurate for checking bearings and general vibration
- Features an innovative sensor design that minimizes measurement variations caused by device angle or contact pressure
- Provides consistent data quality in high and low frequency ranges
- Provides a four-level severity scale to assess the urgency of problems and bearing condition
- Allows you to export data via USB or wirelessly, via the Fluke Connect® mobile app
- Compatible with the Fluke Connect® mobile app that can transmit measurements to your smartphone for real-time sharing
- Allows you to get authorization to take next steps in an instant if machine health is at risk through the Fluke Connect™ mobile app*
- Allows you to view trends in Microsoft® Excel using pre-designed templates
- Measures general vibration (10 Hz to 1000 Hz) for acceleration measurement units, speed and displacement for a wide variety of machines
- Provides Crest Factor+ technology for reliable bearing evaluation using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
- Compare vibration levels to ISO-10816 severity scales and store results in Fluke Connect Cloud
- Features a colored lighting system (green, red) and on-screen feedback to indicate how much pressure should be applied to take measurements
- Measure temperature with the Spot IR sensor to increase diagnostic capabilities
- Maintains and saves up to 3500 measurements in built-in memory
- External accelerometer support (optional) for hard-to-reach places
- Features a built-in flashlight to view measurement locations in dark areas
- Provides a large, high-resolution screen for easy navigation and viewing
| Specifications | |
| Low frequency range (general measurement) | 10 Hz is 1000 Hz |
| High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
| Severity levels | Good, satisfactory, unsatisfactory, unacceptable |
| Vibration limit | 50 g pico (100 g pico-pico) |
| A/D converter | 16 bits |
| Signal to noise ratio | 80dB |
| Sampling rate |
Low frequency: 20,000 Hz High frequency: 80,000 Hz |
| Real-time clock backup | coin battery |
| Sensor | |
| Sensitivity | 100 mV g ± 10 % |
| Measuring range | 0,01 g to 50 g |
| Low frequency range (general measurement) | 10 Hz is 1000 Hz |
| High frequency range | 4,000 Hz to 20,000 Hz |
| Resolution | 0,01 grams |
| Accuracy | At 100 Hz ± 5% of the measured value |
| Amplitude units | |
| Acceleration | g, m/seg² |
| Speed | pulgadas/seg, mm/sec |
| Displacement | thousandths of an inch |
| Infrared thermometer (temperature measurement) | |
| Range | -20 °C a 200 °C (-4 °F a 392 °F) |
| Accuracy | ±2 °C (4 °F) |
| Longitud focal | Fijo, to ~3,8 cm (1,5") |
| External sensor | |
| Note: Fluke supports but does not provide external sensors | |
| Frequency range | 10 Hz is 1000 Hz |
| Bias voltage (to supply power) | 20 V DC and 22 V DC |
| Bias current (to supply power) | Maximum 5mA |
| firmware | |
| Interfaces externas | USB 2.0 communication (full speed) |
| Data capacity | Database in internal flash memory |
| Improvement | via USB |
| Memory | Up to 3,500 measurements |
| radiated emission | |
| electrostatic discharge: explosion | Standard EN 61000-4-2 |
| Electromagnetic interference | Standard EN 61000-4-3 |
| RE | CISPR 11 standard A class |
| Environmental | |
| Operating temperature | -20 °C a 50 °C (-4 °F a 122 °F) |
| Storage temperature | -30 °C a 80 °C (-22 °F a 176 °F) |
| Operating humidity | 10% to 95% RH (non-condensing) |
| Operating/Storage Altitude | Sea level at 3,048 meters (10,000 feet) |
| IP Rating | IP54 |
| Vibration limit | 500g peak |
| Fall test | 1 metro |
| General specifications | |
| Battery Type | AA (2) Lithium iron disulfide |
| Battery duration | 250 measures |
| Size (length x width x height) |
24,1 cm x 7,1 cm x 5,8 cm (9,5 x 2,8 x 2,3 inches) |
| Weight | 0,40 kg (0,89 pounds) |
| Connectors | 7-pin USB mini-B, external sensor connector (SMB connector) |