NAC Extender Remote Power Supply, 12/24Vdc, 8A, 4 Circuits (0500-02360), UL Listed, FM Approved

Skip to product information
1 of 6
  • Listadas UL, aprobadas por FM
  • Compatible con requisitos ADA
  • Compatibilidad con paneles de 12/24 VCC
  • Cuatro circuitos Clase A/B indicadores
  • Memoria de problemas del circuito de señal

Low stock: 9 left

Modelo: FN-842-ULADA-R

Proveedor: HOCHIKI

Código SAT: 46191505

Tax included.
Our Commitment ×
By purchasing this product you are making a positive impact. We contribute of each sale and we’ve partnered with WeAreGoodness.io
View full details

General characteristics

  • UL Listed.
  • Approved FM.
  • Compliant with ADA requirements.
  • Primary applications include Notification Appliance Circuit (NAC) expansion.
  • Provides auxiliary power to support system accessories.
  • They can be connected to any 12 or 24 Vdc fire alarm control panel.
  • Two (2) Class A or (2) Class B FACP entries.
  • Two (2) NC dry contact trigger inputs.
  • Four (4) Class A or (4) Class B indicating circuits.
  • Two (2) or more Class B outputs can be connected in parallel during power on an indicator circuit.
  • One (1) assistant. Power output at 1 A supply current (with or without battery backup)
  • Signal Circuit Trouble Memory – Makes it easy to locate intermittent system problems and eliminate costly and unnecessary service calls.
  • The LEDs indicate that a previous fault (short circuit, open, ground) has occurred on one or more outputs of the signaling circuit.
  • The 2-wire horn/strobe sync mode allows audible notification devices (horns) to be silenced while visual notification devices (strobes) continue to operate.
  • Horn/strobe sync protocols include: Gentex, System Sensor, Faraday, Wheelock and Amseco.
  • Temporary mode 3.
  • March Time Mode
  • Steady mode.
  • Input-to-output follower mode (maintains synchronization of notification device circuits).
  • Input fuse rating @ 3.5 amps/250V
  • Filtered and electronically regulated output
  • Protection against short circuits and thermal overload
  • AC fault supervision (type "C" contacts)
  • Low battery monitoring (form "C" contacts)
  • Battery presence supervision (form "C" contacts)
  • Built-in charger for sealed lead acid or gel batteries.
  • Automatic switch to backup battery when AC power fails ( Power Sonic PS-12120-F2 batteries)
  • Zero voltage drop when switching to backup battery
  • AC input and DC output LED indicators
  • Supports up to two (2) 12V/12 AH batteries ( use Power Sonic PS-12120-F2 batteries)

Specifications

  • Output 24 or 12 Vdc nominal at 8 A max.
  • Input 115 Vac/60 Hz.
  • (4) Class A or (4) Class B outlets
  • Cabinet Size: 18" Height x 14.5" Width x 4.625" Depth