{"product_id":"switch-next-generation-data-center-24-puertos-qspf56-200g-y-8-puertos-qspf-dd-400g","title":"Switch Next-Generation Data Center, 24 Puertos QSPF56 200G y 8 Puertos QSPF-DD 400G","description":"\u003cdiv style=\"width: 100%; max-width: 1360px; margin: 0 auto; font-family: sans-serif; line-height: 1.7; color: inherit; background-color: transparent; box-sizing: border-box; padding: 5px;\"\u003e \u003c!-- ========== IMAGEN PRINCIPAL ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; display: flex; justify-content: center;\"\u003e \u003cimg style=\"width: 100%; max-width: 1360px; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; object-fit: cover; box-shadow: 0 12px 32px rgba(0, 0, 0, 0.06);\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/04\/2251\/Banner_Ruijie_Empresarial_froala_6aeb73fae010c.jpg\" alt=\"Ruijie\"\u003e \u003c\/div\u003e \u003c!-- ========== TITULO Y DESCRIPCION ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; text-align: center;\"\u003e \u003ch2 style=\"font-size: 28px; font-weight: bold; letter-spacing: -0.5px; color: inherit; margin: 0 0 15px 0;\"\u003eSwitch Ruijie modelo: RG-S6580-24DC8QC\u003c\/h2\u003e \u003cp style=\"margin: 0 auto; max-width: 800px; font-size: 16px; opacity: 0.8;\"\u003eEl RG-S6580-24DC8QC es un switch de acceso para centros de datos con 24 puertos QSFP56 de 200G para servidores de IA y 8 uplinks QSFP-DD de 400G en 1 RU, con 16.0 Tbps de conmutación. Soporta RDMA con PFC\/ECN y VXLAN, y llega con 2 fuentes 1+1 y 6 ventiladores 5+1 intercambiables en caliente ya instalados.\u003c\/p\u003e \u003c\/div\u003e \u003c!-- ========== CARACTERISTICAS GENERALES ========== --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 40px; margin-bottom: 40px; align-items: center; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 350px; min-width: 280px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; object-fit: cover; box-shadow: 0 8px 24px rgba(0, 0, 0, 0.05);\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/233432\/portada_0S1000.PNG\" alt=\"RG-S6580-24DC8QC\"\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 350px; min-width: 280px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.5px; font-weight: bold; opacity: 0.6; margin-bottom: 10px;\"\u003eResumen Técnico\u003c\/div\u003e \u003ch3 style=\"font-size: 24px; font-weight: bold; margin: 0 0 20px 0; color: inherit;\"\u003eCaracterísticas Generales\u003c\/h3\u003e \u003cul style=\"padding-left: 0; margin: 0; font-size: 15px; color: inherit; list-style: none;\"\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eTipo:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003eSwitch Capa 3 de acceso de 200G con uplinks de 400G para centro de datos (sin PoE)\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003ePuertos:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003e24 QSFP56 40\/100\/200 GE (un puerto de 200G se divide en 2 de 100G) y 8 QSFP-DD 100\/400 GE\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eAlimentación:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003e2 módulos de fuente RG-PA1200I-F instalados, con redundancia 1+1, y 6 ventiladores M1HFAN II-F instalados, con redundancia 5+1\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eConfiguración:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003eCLI (consola, Telnet, SSH), SNMP v1\/v2c\/v3, NETCONF, Python y ZTP\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eGarantía:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003e3 años\u003c\/span\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== TARJETAS DE ESPECIFICACIONES ========== --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003c!-- Tarjeta Desempeño --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003eDesempeño\u003c\/div\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCapacidad de switching:\u003c\/strong\u003e 16.0 Tbps\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTasa de reenvío:\u003c\/strong\u003e 2680 Mpps\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e Cuatro núcleos a 2.9 GHz\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMemoria:\u003c\/strong\u003e 8 GB DDR4 \/ 64 GB SSD \/ 16 MB BootROM\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eJumbo frame:\u003c\/strong\u003e 9 KB\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCentro de datos:\u003c\/strong\u003e RDMA, PFC, ECN, VXLAN bridge y gateway, PFC y ECN sobre VXLAN\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Tarjeta Puertos y Módulos --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003ePuertos y Módulos\u003c\/div\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePuertos de servicio:\u003c\/strong\u003e 24 x QSFP56 40\/100\/200 GE y 8 x QSFP-DD 100\/400 GE\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDivisión de puertos:\u003c\/strong\u003e Un puerto de 200G se puede dividir en 2 puertos de 100G (servidores de 100G y de 200G en el mismo equipo)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eGestión:\u003c\/strong\u003e 1 consola RJ45 y 1 puerto MGMT RJ45\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eUSB:\u003c\/strong\u003e 1 puerto USB 2.0 Tipo A; conexión en caliente\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRanuras de fuente:\u003c\/strong\u003e 2 módulos RG-PA1200I-F instalados (CA 100-127 V y 200-240 V o HVDC 240 V); redundancia 1+1 y cambio en caliente\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVentiladores:\u003c\/strong\u003e 6 módulos M1HFAN II-F instalados con redundancia 5+1; cambio en caliente; velocidad automática\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eFlujo de aire:\u003c\/strong\u003e De frente a atrás (entrada por el lado de los puertos)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTransceptores:\u003c\/strong\u003e 100GE: SR 100 m, LR4 10 km, iLR4 2 km, ER4 40 km y AOC de 5 y 10 m; 400GE: SR8 100 m, DR4 500 m, FR4 2 km y ZR 80 km\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Tarjeta Fisica --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003eFísicas y Eléctricas\u003c\/div\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAlimentación:\u003c\/strong\u003e 2 módulos RG-PA1200I-F: 100-127 V CA y 200-240 V CA, 50\/60 Hz (13.8 A \/ 8.5 A), o 240 V HVDC, 6.5 A; salida de 1,000 W (100-127 V CA) o 1,300 W (200-240 V CA y HVDC)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eConsumo máximo:\u003c\/strong\u003e 850 W (típico 700 W \/ estático 300 W)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDimensiones:\u003c\/strong\u003e 442 x 670 x 43.6 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltura en rack:\u003c\/strong\u003e 1 RU (profundidad libre en rack \u0026gt; 800 mm)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePeso:\u003c\/strong\u003e 11 kg (con 2 fuentes y 6 ventiladores)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTemperatura de operación:\u003c\/strong\u003e 0 °C a 40 °C (de 1,800 a 5,000 m baja 1 °C por cada 200 m)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTemperatura de almacenamiento:\u003c\/strong\u003e -40 °C a 70 °C\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHumedad de operación:\u003c\/strong\u003e 10% a 90% RH sin condensación\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltitud de operación:\u003c\/strong\u003e Hasta 5,000 m\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisipación:\u003c\/strong\u003e Ventiladores; máx. 2,900 BTU\/h (típico 2,388 BTU\/h)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRuido:\u003c\/strong\u003e \u0026lt; 78 dB a 27 °C\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 55.35 años\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProtección contra descargas:\u003c\/strong\u003e Puerto MGMT 4 kV en modo común; conector de alimentación 2 kV en modo común y 1 kV diferencial\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMontaje:\u003c\/strong\u003e Rack de 19 pulgadas (rieles guía incluidos con el chasis)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Tarjeta Paquete --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003eContenido del Paquete\u003c\/div\u003e \u003col style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eSwitch RG-S6580-24DC8QC (chasis)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e2 módulos de fuente RG-PA1200I-F instalados\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e6 ventiladores M1HFAN II-F instalados\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eCable de tierra amarillo-verde\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eRieles guía de montaje en rack\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eGuía rápida de instalación, lista de empaque y documentación\u003c\/li\u003e \u003c\/ol\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== RECURSOS Y DOCUMENTACION ========== --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 220px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 20px; box-sizing: border-box; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 12px; color: inherit;\"\u003eDocumentación\u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; font-size: 14px;\"\u003e \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6580-24DC8QC_Datasheet_2026-11-02.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHoja de Especificaciones\u003c\/a\u003e \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6580-24DC8QC_Hardware_Installation_Guide_V2.5.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGuía de Instalación de Hardware (V2.5, inglés)\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 220px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 20px; box-sizing: border-box; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 12px; color: inherit;\"\u003eAccesorios Recomendados\u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; font-size: 14px;\"\u003e \u003cspan style=\"opacity: 0.8;\"\u003e\u003ca href=\"https:\/\/www.syscom.mx\/producto\/RG-PA1200I-F-RUIJIE-233433.html\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMódulo de fuente 1200 W de reemplazo, CA o HVDC 240 V: RG-PA1200I-F\u003c\/a\u003e\u003c\/span\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 220px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 20px; box-sizing: border-box; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 12px; color: inherit;\"\u003eEnlaces Útiles\u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; font-size: 14px;\"\u003e\n\u003ca style=\"color: inherit; text-decoration: none; opacity: 0.8; border-bottom: 1px dashed currentColor; padding-bottom: 2px; width: fit-content;\" href=\"https:\/\/cloud-la.ruijienetworks.com\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePlataforma Ruijie Cloud\u003c\/a\u003e \u003cspan style=\"opacity: 0.8;\"\u003eAPP: \u003ca style=\"color: inherit; text-decoration: none; font-weight: bold;\" href=\"https:\/\/play.google.com\/store\/apps\/details?id=cn.com.ruijie.cloudapp\u0026amp;hl=es_MX\u0026amp;pli=1\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eAndroid\u003c\/a\u003e \/ \u003ca style=\"color: inherit; text-decoration: none; font-weight: bold;\" href=\"https:\/\/apps.apple.com\/us\/app\/ruijie-reyee\/id1423429270\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eiOS\u003c\/a\u003e\u003c\/span\u003e \u003ca style=\"color: inherit; text-decoration: none; opacity: 0.8; border-bottom: 1px dashed currentColor; padding-bottom: 2px; width: fit-content;\" href=\"https:\/\/soporte.syscom.mx\/es\/collections\/3797236-ruijie-networks\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManuales y Guías Rápidas\u003c\/a\u003e\n\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== PROTOCOLOS ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003ch2 style=\"font-size: 22px; font-weight: bold; margin: 0 0 20px 0; color: inherit;\"\u003eProtocolos y Funciones de Software\u003c\/h2\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eCapa 2\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003e802.3x, 802.3ad (LACP), 802.1p, 802.1Q, STP\/RSTP\/MSTP, jumbo frame de 9 KB\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eCapa 3 \/ Ruteo\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eBGP4, OSPFv2\/v3, RIPv1\/v2\/RIPng, BGP4+, LPM, PBR, route-policy, ECMP y WCMP, VRRP (IPv4 e IPv6), rutas estáticas; IPv6: ND, ICMPv6, PMTU, DNSv6, DHCPv6, ACLv6; DHCP cliente\/relay\/servidor, DNS y ARP proxy\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eCentro de datos\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003ePFC, ECN y otras funciones de centro de datos, RDMA, VXLAN bridge y gateway, VXLAN IPv4 e IPv6 sobre IPv4, PFC y ECN sobre VXLAN; visualización con gRPC, sFlow e IPFIX\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eQoS\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003ePriorización 802.1p\/DSCP\/ToS, clasificación por ACL y remarcado, SP\/WRR\/WFQ\/DRR\/SP+WRR\/SP+WFQ\/SP+DRR, WRED y tail drop\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eSeguridad\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eNFPP, CPP, RADIUS\/TACACS, filtrado IPv4\/IPv6 por ACL básica, extendida o por VLAN, autenticación MD5 en OSPF y BGPv4, Telnet restringido por IP, supresión de broadcast, usuarios jerárquicos\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eConfiabilidad\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eGR para RIP\/OSPF\/BGP, BFD, DLDP, REUP, RLDP, fuentes y ventiladores en redundancia con intercambio en caliente\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eGestión\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSNMP v1\/v2c\/v3, NETCONF, Telnet, consola, MGMT, RMON, SSH v1\/v2, FTP\/TFTP, NTP, Syslog, SPAN\/RSPAN\/ERSPAN, ZTP, Python y alarmas de fuente, ventilador y temperatura\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== GALERIA DE IMAGENES ========== --\u003e \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 24px; margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003cdiv\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; box-shadow: 0 8px 24px rgba(0, 0, 0, 0.05); aspect-ratio: 2800 \/ 1600; object-fit: cover; object-position: center;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6580-24DC8QC_g1_froala_6aeffdf3c7621.webp\" alt=\"RG-S6580-24DC8QC Switch Ruijie de 200G para centro de datos con 24 puertos QSFP56 y 8 QSFP-DD de 400G\"\u003e\u003c\/div\u003e \u003cdiv\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; box-shadow: 0 8px 24px rgba(0, 0, 0, 0.05); aspect-ratio: 2800 \/ 1600; object-fit: cover; object-position: center;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6580-24DC8QC_g2_froala_6aeffdf4f0451.webp\" alt=\"Vista posterior del switch Ruijie RG-S6580-24DC8QC con dos fuentes en redundancia 1+1\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== PREGUNTAS FRECUENTES ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003ch2 style=\"font-size: 22px; font-weight: bold; margin: 0 0 20px 0; color: inherit;\"\u003ePreguntas Frecuentes\u003c\/h2\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Incluye fuentes y ventiladores?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSí, según la ficha: el chasis llega con 2 módulos RG-PA1200I-F (1,200 W) y 6 ventiladores M1HFAN II-F instalados, en redundancia 1+1 y 5+1, todos intercambiables en caliente.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Puedo conectar servidores de 100G y de 200G?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSí. Los 24 puertos QSFP56 son de 200G y cada uno puede dividirse en 2 puertos de 100G, con lo que se atienden servidores de 100G y servidores GPU de 200G en el mismo switch.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Sirve para RDMA y cargas de IA?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSí. Soporta RDMA con PFC y ECN para Ethernet sin pérdidas, incluso sobre VXLAN, y visualización con gRPC, sFlow e IPFIX.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Qué uplinks tiene?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003e8 puertos QSFP-DD de 100G\/400G con transceptores de 400G SR8 (100 m), DR4 (500 m), FR4 (2 km) o ZR (80 km); la ficha remite a la matriz de compatibilidad de la serie RG-S6580.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Qué diferencia hay con el RG-S6580-48CQ8QC?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eEl RG-S6580-24DC8QC trae 24 puertos de 200G (850 W máx., 11 kg); el RG-S6580-48CQ8QC trae 48 puertos DSFP de 100G (742 W máx., 11.5 kg). Ambos tienen 8 QSFP-DD de 400G y 16.0 Tbps.\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"RUIJIE","offers":[{"title":"Default Title","offer_id":46366592401653,"sku":"RG-S6580-24DC8QC","price":586482.68,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S400_2a7d8692-ad64-4b7c-9e6c-90849016981f.png?v=1789297117","url":"https:\/\/prolink.mx\/products\/switch-next-generation-data-center-24-puertos-qspf56-200g-y-8-puertos-qspf-dd-400g","provider":"ProLink","version":"1.0","type":"link"}