{"product_id":"switch-dci-para-data-center-32-puertos-qsfp28-100g-vxlan-que-permite-una-transmision-ilimitada-de-datos-y-una-asignacion-y-programacion-flexible-de-recursos","title":"Switch DCI para Data Center , 32 Puertos QSFP28 100G, VXLAN que Permite una Transmisión Ilimitada de Datos y una Asignación y Programación Flexible de Recursos.","description":"\u003cdiv style=\"width: 100%; max-width: 1360px; margin: 0 auto; font-family: sans-serif; line-height: 1.7; color: inherit; background-color: transparent; box-sizing: border-box; padding: 5px;\"\u003e \u003c!-- ========== IMAGEN PRINCIPAL ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; display: flex; justify-content: center;\"\u003e \u003cimg style=\"width: 100%; max-width: 1360px; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; object-fit: cover; box-shadow: 0 12px 32px rgba(0, 0, 0, 0.06);\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/04\/2251\/Banner_Ruijie_Empresarial_froala_6aeb73fae010c.jpg\" alt=\"Ruijie\"\u003e \u003c\/div\u003e \u003c!-- ========== TITULO Y DESCRIPCION ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; text-align: center;\"\u003e \u003ch2 style=\"font-size: 28px; font-weight: bold; letter-spacing: -0.5px; color: inherit; margin: 0 0 15px 0;\"\u003eSwitch Ruijie modelo: RG-S6510-32CQ\u003c\/h2\u003e \u003cp style=\"margin: 0 auto; max-width: 800px; font-size: 16px; opacity: 0.8;\"\u003eEl RG-S6510-32CQ es un switch de 100G para centros de datos con 32 puertos QSFP28 en 1 RU, pensado como spine o leaf de alta densidad. Entrega 6.4 Tbps con 32 MB de buffer, VXLAN con EVPN, M-LAG y RDMA con PFC\/ECN; fuentes 1+1 y ventiladores 4+1 intercambiables en caliente (módulos que se compran por separado).\u003c\/p\u003e \u003c\/div\u003e \u003c!-- ========== CARACTERISTICAS GENERALES ========== --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 40px; margin-bottom: 40px; align-items: center; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 350px; min-width: 280px;\"\u003e \u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; object-fit: cover; box-shadow: 0 8px 24px rgba(0, 0, 0, 0.05);\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/AI\/UPSCALE\/233437\/portada_0S1000.PNG\" alt=\"RG-S6510-32CQ\"\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 350px; min-width: 280px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.5px; font-weight: bold; opacity: 0.6; margin-bottom: 10px;\"\u003eResumen Técnico\u003c\/div\u003e \u003ch3 style=\"font-size: 24px; font-weight: bold; margin: 0 0 20px 0; color: inherit;\"\u003eCaracterísticas Generales\u003c\/h3\u003e \u003cul style=\"padding-left: 0; margin: 0; font-size: 15px; color: inherit; list-style: none;\"\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eTipo:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003eSwitch Capa 3 de 100G para centro de datos, spine o leaf (sin PoE)\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003ePuertos:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003e32 QSFP28 100 GE (compatibles con 40 GE)\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eStacking \/ virtualización:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003eVSU y M-LAG (enlaces activo-activo entre equipos)\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eAlimentación:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003e2 ranuras para módulos de fuente (RG-PA550I-F o RG-PD800I-F) con redundancia 1+1 y 5 ranuras de ventilador M1HFAN I-F con redundancia 4+1 (módulos por separado)\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eConfiguración:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003eCLI (consola, Telnet, SSH), SNMP v1\/v2c\/v3, NETCONF, Python, ZTP y Telemetry\u003c\/span\u003e\n\u003c\/li\u003e \u003cli style=\"margin-bottom: 12px; display: flex; gap: 10px;\"\u003e\n\u003cstrong style=\"opacity: 0.9; min-width: 130px;\"\u003eGarantía:\u003c\/strong\u003e \u003cspan style=\"opacity: 0.8;\"\u003e3 años\u003c\/span\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== TARJETAS DE ESPECIFICACIONES ========== --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003c!-- Tarjeta Desempeño --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003eDesempeño\u003c\/div\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCapacidad de switching:\u003c\/strong\u003e 6.4 Tbps\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTasa de reenvío:\u003c\/strong\u003e 2030 Mpps\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e Cuatro núcleos a 2.9 GHz (versiones desde V1.50; 2.2 GHz en anteriores)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMemoria:\u003c\/strong\u003e 8 GB DDR4 \/ 240 GB SSD \/ 16 MB BootROM\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBuffer:\u003c\/strong\u003e 32 MB con programación avanzada de buffer\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eJumbo frame:\u003c\/strong\u003e 9 KB\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eCentro de datos:\u003c\/strong\u003e VXLAN, EVPN VXLAN, M-LAG, RDMA, PFC, ECN y OpenFlow 1.3\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Tarjeta Puertos y Módulos --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003ePuertos y Módulos\u003c\/div\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePuertos de servicio:\u003c\/strong\u003e 32 x QSFP28 100 GE (compatibles con 40 GE)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eGestión:\u003c\/strong\u003e 1 consola RJ45 y 1 puerto MGMT RJ45\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eUSB:\u003c\/strong\u003e 1 puerto USB 2.0 Tipo A; conexión en caliente\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRanuras de fuente:\u003c\/strong\u003e 2 módulos enchufables: RG-PA550I-F (550 W, CA 100-240 V o HVDC 240 V) o RG-PD800I-F (800 W, -48 V CD); redundancia 1+1; se requiere al menos 1\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eVentiladores:\u003c\/strong\u003e 5 módulos M1HFAN I-F enchufables con redundancia 4+1; velocidad automática\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eFlujo de aire:\u003c\/strong\u003e De frente a atrás (entrada por el lado de los puertos)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eIntercambio en caliente:\u003c\/strong\u003e Tarjetas, fuentes, ventiladores, USB y cables\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTransceptores:\u003c\/strong\u003e 40GE: SR 150 m, LSR 400 m, LR4 10 km, iLR4 2 km, LX4 2 km y AOC de 5 y 30 m; 100GE: SR 100 m, LR4 10 km, iLR4 2 km, ER4 40 km y AOC de 5 y 10 m\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Tarjeta Fisica --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003eFísicas y Eléctricas\u003c\/div\u003e \u003cul style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAlimentación:\u003c\/strong\u003e 2 módulos enchufables (se compran por separado). RG-PA550I-F: 100-240 V CA, 50\/60 Hz, 7.2 a 3.5 A, o 240 V HVDC. RG-PD800I-F: -48 V CD (-36 a -72 V), 23 A\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eConsumo máximo:\u003c\/strong\u003e 450 W (típico 270 W \/ estático 150 W)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDimensiones:\u003c\/strong\u003e 442 x 560 x 44 mm\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltura en rack:\u003c\/strong\u003e 1 RU (profundidad libre en rack \u0026gt; 800 mm)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePeso:\u003c\/strong\u003e 8.4 kg (solo chasis) \/ 11.4 kg (con 2 fuentes y 5 ventiladores)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTemperatura de operación:\u003c\/strong\u003e 0 °C a 40 °C (de 3,000 a 5,000 m baja 1 °C por cada 200 m)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eTemperatura de almacenamiento:\u003c\/strong\u003e -40 °C a 70 °C\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHumedad de operación:\u003c\/strong\u003e 10% a 90% RH sin condensación\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltitud de operación:\u003c\/strong\u003e Hasta 5,000 m\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDisipación:\u003c\/strong\u003e Ventiladores; máx. 1,535 BTU\/h (típico 921 BTU\/h)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eRuido:\u003c\/strong\u003e \u0026lt; 78 dB a 27 °C\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 35.08 años\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eProtección contra descargas:\u003c\/strong\u003e Puerto MGMT 2 kV en modo común; conector de alimentación 2 kV en modo común y 1 kV diferencial\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eMontaje:\u003c\/strong\u003e Rack de 19 pulgadas (rieles guía incluidos con el chasis)\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c!-- Tarjeta Paquete --\u003e \u003cdiv style=\"flex: 1 1 280px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 16px; background-color: rgba(128, 128, 128, 0.02); box-shadow: 0 4px 20px rgba(0, 0, 0, 0.02); display: flex; flex-direction: column; box-sizing: border-box; padding: 24px;\"\u003e \u003cdiv style=\"font-size: 13px; text-transform: uppercase; letter-spacing: 1.2px; font-weight: bold; opacity: 0.6; border-bottom: 1px solid rgba(150, 150, 150, 0.15); padding-bottom: 12px; margin-bottom: 20px;\"\u003eContenido del Paquete\u003c\/div\u003e \u003col style=\"padding-left: 20px; margin: 0; font-size: 14px; opacity: 0.85;\"\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eSwitch RG-S6510-32CQ (chasis)\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eCable de tierra amarillo-verde\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eRieles guía de montaje en rack\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eGuía rápida de instalación, lista de empaque y documentación\u003c\/li\u003e \u003cli style=\"margin-bottom: 8px;\"\u003eMódulos de fuente (RG-PA550I-F o RG-PD800I-F) y ventiladores M1HFAN I-F: no incluidos, se compran por separado\u003c\/li\u003e \u003c\/ol\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== RECURSOS Y DOCUMENTACION ========== --\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 24px; margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 220px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 20px; box-sizing: border-box; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 12px; color: inherit;\"\u003eDocumentación\u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; font-size: 14px;\"\u003e \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6510-32CQ_Datasheet_2026-09-22.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eHoja de Especificaciones\u003c\/a\u003e \u003ca href=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6510-32CQ_Hardware_Installation_Guide_V2.5.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eGuía de Instalación de Hardware (V2.5, inglés)\u003c\/a\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 220px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 20px; box-sizing: border-box; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 12px; color: inherit;\"\u003eAccesorios Recomendados\u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; font-size: 14px;\"\u003e \u003cspan style=\"opacity: 0.8;\"\u003e\u003ca href=\"https:\/\/www.syscom.mx\/producto\/RG-PA550I-F-RUIJIE-233438.html\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eMódulo de fuente 550 W, CA 100-240 V o HVDC 240 V (se requiere al menos 1): RG-PA550I-F\u003c\/a\u003e\u003c\/span\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 250px; min-width: 220px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 20px; box-sizing: border-box; display: flex; flex-direction: column;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 12px; color: inherit;\"\u003eEnlaces Útiles\u003c\/div\u003e \u003cdiv style=\"display: flex; flex-direction: column; gap: 10px; font-size: 14px;\"\u003e\n\u003ca style=\"color: inherit; text-decoration: none; opacity: 0.8; border-bottom: 1px dashed currentColor; padding-bottom: 2px; width: fit-content;\" href=\"https:\/\/cloud-la.ruijienetworks.com\/\" target=\"_blank\" rel=\"noopener noreferrer\"\u003ePlataforma Ruijie Cloud\u003c\/a\u003e \u003cspan style=\"opacity: 0.8;\"\u003eAPP: \u003ca style=\"color: inherit; text-decoration: none; font-weight: bold;\" href=\"https:\/\/play.google.com\/store\/apps\/details?id=cn.com.ruijie.cloudapp\u0026amp;hl=es_MX\u0026amp;pli=1\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eAndroid\u003c\/a\u003e \/ \u003ca style=\"color: inherit; text-decoration: none; font-weight: bold;\" href=\"https:\/\/apps.apple.com\/us\/app\/ruijie-reyee\/id1423429270\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eiOS\u003c\/a\u003e\u003c\/span\u003e \u003ca style=\"color: inherit; text-decoration: none; opacity: 0.8; border-bottom: 1px dashed currentColor; padding-bottom: 2px; width: fit-content;\" href=\"https:\/\/soporte.syscom.mx\/es\/collections\/3797236-ruijie-networks\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eManuales y Guías Rápidas\u003c\/a\u003e\n\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== PROTOCOLOS ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003ch2 style=\"font-size: 22px; font-weight: bold; margin: 0 0 20px 0; color: inherit;\"\u003eProtocolos y Funciones de Software\u003c\/h2\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eCapa 2\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003e802.3ad (LACP), 802.1p, 802.1Q, STP\/RSTP\/MSTP, IGMP snooping, MLD snooping, jumbo frame de 9 KB, QinQ y QinQ selectivo, GVRP\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eCapa 3 \/ Ruteo\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eBGP4\/MBGP, OSPFv2\/v3, RIPv1\/v2\/RIPng, BGP4+, LPM, PBR, route-policy, ECMP y WCMP, VRRP (IPv4 e IPv6), rutas estáticas, túneles manuales, automáticos, IPv4 sobre IPv6 e ISATAP; IPv6: ND, ICMPv6, PMTU, DNSv6, DHCPv6, ACLv6; DHCP cliente\/relay\/servidor, DNS, UDP relay y ARP proxy\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eMulticast\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eIGMP v1\/v2\/v3, DVMRP, PIM-SSM\/SM\/DM, MSDP, Any-RP, PIM-SMv6, MLD v1\/v2\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eCentro de datos\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eVXLAN routing y bridging, VXLAN IPv6 sobre IPv4 y EVPN VXLAN, PFC, ECN y RDMA, M-LAG, OpenFlow 1.3; visualización con gRPC, sFlow e INT\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eQoS\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003ePriorización 802.1p\/DSCP\/ToS, clasificación por ACL y remarcado, SP\/WRR\/DRR\/SP+WRR\/SP+DRR, WRED y tail drop, monitoreo de buffer e identificación de ráfagas\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eSeguridad\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eNFPP, CPP, defensa contra DDoS, detección de paquetes ilegítimos, prevención de spoofing y escaneo de IP, RADIUS\/TACACS, filtrado IPv4\/IPv6 por ACL básica, extendida o por VLAN, autenticación MD5 en OSPF, RIPv2 y BGPv4, Telnet restringido por IP, uRPF, supresión de broadcast, DHCP snooping, anti ARP spoofing y ARP check\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eConfiabilidad\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eVSU, GR para RIP\/OSPF\/BGP, BFD, DLDP, REUP, RLDP, fuentes y ventiladores en redundancia con intercambio en caliente\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003cdiv style=\"font-size: 15px; font-weight: bold; margin-bottom: 6px; color: inherit;\"\u003eGestión\u003c\/div\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSNMP v1\/v2c\/v3, NETCONF, Telnet, consola, MGMT, RMON, SSH v1\/v2, FTP\/TFTP, NTP, Syslog, SPAN\/RSPAN\/ERSPAN, Telemetry, ZTP, Python y alarmas de fuente, ventilador y temperatura\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== GALERIA DE IMAGENES ========== --\u003e \u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 24px; margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003cdiv\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; box-shadow: 0 8px 24px rgba(0, 0, 0, 0.05); aspect-ratio: 2800 \/ 1600; object-fit: cover; object-position: center;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6510-32CQ_g1_froala_6aeffc2822b64.webp\" alt=\"RG-S6510-32CQ Switch Ruijie para centro de datos con 32 puertos QSFP28 de 100G\"\u003e\u003c\/div\u003e \u003cdiv\u003e\u003cimg style=\"width: 100%; height: auto; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 5px; padding: 5px; background-color: rgba(128, 128, 128, 0.05); box-sizing: border-box; box-shadow: 0 8px 24px rgba(0, 0, 0, 0.05); aspect-ratio: 2800 \/ 1600; object-fit: cover; object-position: center;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/ftp\/2026\/11\/07\/2251\/RG-S6510-32CQ_g2_froala_6aeffc294692c.webp\" alt=\"Vista posterior del switch Ruijie RG-S6510-32CQ con 2 fuentes y 5 ventiladores y su flujo de aire\"\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c!-- ========== PREGUNTAS FRECUENTES ========== --\u003e \u003cdiv style=\"margin-bottom: 40px; box-sizing: border-box;\"\u003e \u003ch2 style=\"font-size: 22px; font-weight: bold; margin: 0 0 20px 0; color: inherit;\"\u003ePreguntas Frecuentes\u003c\/h2\u003e \u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; box-sizing: border-box;\"\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Incluye fuentes y ventiladores?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eNo. El chasis tiene 2 ranuras de fuente y 5 de ventilador; según la ficha se ordenan por separado: la fuente RG-PA550I-F (550 W) y el ventilador M1HFAN I-F. Con 2 fuentes trabaja en redundancia 1+1 y con 5 ventiladores en 4+1.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Sirve para RDMA y cargas de IA o almacenamiento?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSí. Soporta RDMA con PFC y ECN para Ethernet sin pérdidas, 32 MB de buffer con programación avanzada y visualización de tráfico por hardware (gRPC, sFlow e INT).\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Soporta VXLAN y EVPN para Spine-Leaf?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSí. Ofrece VXLAN routing y bridging, EVPN VXLAN y M-LAG (enlaces activo-activo hacia servidores), con ruteo BGP4, OSPFv2\/v3 y ECMP.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Los puertos de 100G aceptan módulos de 40G?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eSí. La ficha indica que los puertos de 100GE son compatibles con 40GE; se usan transceptores QSFP28 (100G) o QSFP+ (40G) según el enlace.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv style=\"flex: 1 1 400px; min-width: 260px; border: 1px solid rgba(150, 150, 150, 0.15); border-radius: 12px; padding: 18px 20px; box-sizing: border-box;\"\u003e \u003ch3 style=\"font-size: 16px; font-weight: bold; margin: 0 0 8px 0; color: inherit;\"\u003e¿Qué diferencia hay con el RG-S6510-48VS8CQ?\u003c\/h3\u003e \u003cp style=\"margin: 0; font-size: 14px; opacity: 0.85;\"\u003eEl RG-S6510-32CQ da 32 puertos de 100G (6.4 Tbps, 450 W máx., 5 ventiladores); el RG-S6510-48VS8CQ da 48 puertos de 10\/25G más 8 de 40\/100G (4.0 Tbps, 300 W máx., 4 ventiladores).\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e","brand":"RUIJIE","offers":[{"title":"Default Title","offer_id":46366592237813,"sku":"RG-S6510-32CQ","price":418899.59,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S400_eaa4059c-a5d0-4a11-a373-4910c54123ce.png?v=1789297089","url":"https:\/\/prolink.mx\/products\/switch-dci-para-data-center-32-puertos-qsfp28-100g-vxlan-que-permite-una-transmision-ilimitada-de-datos-y-una-asignacion-y-programacion-flexible-de-recursos","provider":"ProLink","version":"1.0","type":"link"}