{"product_id":"ups-de-2000va-1800w-topologia-on-line-doble-conversion-entrada-y-salida-de-120-vca-clavija-de-entrada-nema-5-20p-pantalla-lcd-configurable-formato-rack-torre","title":"2000VA\/1800W UPS \/ Double Conversion On-Line Topology \/ 120 Vac Input and Output \/ NEMA 5-20P Input Plug \/ Configurable LCD Screen \/ Rack\/Tower Format","description":"\u003cp\u003e\u003cspan style=\"color: #333333; font-family: 'Helvetica Neue'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif; font-size: 14px; background-color: #ffffff;\"\u003eThe On-Line topology UPS (double conversion) is the high-density version of epcom Power Line\u0026amp;comma; Designed for 100\/110\/115\/120\/127 VAC voltage applications. It is equipped with power factor correction (PFC) at the input, power factor of 0.9 at the output\u0026amp;comma; offering high levels of reliability and protection for IT systems\u0026amp;comma; telecommunications equipment\u0026amp;comma; mission critical medical equipment and systems\u0026amp;comma; It is convertible to Rack or Tower and only takes 2U Rack units.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr style=\"line-height: 20.8px;\"\u003e \u003cstrong\u003eGeneral characteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Capacity: 2000 VA \/ 1800 W.\u003c\/li\u003e\n\u003cli\u003e Topology: On-Line\u003c\/li\u003e\n\u003cli\u003e With LCD screen.\u003c\/li\u003e\n\u003cli\u003e Wave type: Pure sine wave.\u003c\/li\u003e\n\u003cli\u003e Battery: 4 x 12V\/9Ah.\u003c\/li\u003e\n\u003cli\u003e Dimensions (mm): 88 x 440 x 720 (Height x Width x Depth)\u003c\/li\u003e\n\u003cli\u003e Output power factor: 0.9\u003c\/li\u003e  \u003cli\u003eVoltage Regulator: 95 - 135 VAC.\u003c\/li\u003e\n\u003cli\u003e Voltage Output: 100 V \/ 110 V \/ 115 V \/ 120 V \/ 127V AC (Configurable via LCD).\u003c\/li\u003e\n\u003cli\u003e Option for battery bank.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eNOTE:\u003c\/strong\u003e On the power supply terminals INPUT corresponds to the input and OUTPUT corresponds to the output.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003e*1 year warranty.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"container\" style=\"background-image: url('http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_background_1.png'); background-repeat: no-repeat; background-attachment: scroll; background-position: center top; h2\u0026amp;comma;h4{color: #e70000;\"\u003e\u003cdiv class=\"background\"\u003e\n\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-sm-12 text-center\"\u003e\n\u003ccenter\u003e\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_logotipo.png\" width=\"100px\"\u003e\u003c\/center\u003e\n\u003cp style=\"font-size: medium; font-weight: 400; text-align: center;\"\u003e \u003ca style=\"color: #000000;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/acordova\/epcom%20Power%20line\/BACK%20UP.xlsx\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"font-family: impact\u0026amp;comma; sans-serif; font-size: 24pt;\"\u003e\u003cstrong\u003eDOWNLOAD THE BACKUP TIME CALCULATOR\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"font-size: medium; font-weight: 400; text-align: center;\"\u003e \u003ca style=\"color: #000000;\" href=\"https:\/\/ftp3.syscom.mx\/usuarios\/acordova\/epcom%20Power%20line\/BACK%20UP.xlsx\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan style=\"font-family: impact\u0026amp;comma; sans-serif; font-size: 24pt;\"\u003e\u003cstrong\u003eHERE!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch1\u003e The Most Reliable UPS Line \u003c\/h1\u003e\n\u003ccenter\u003e\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_header.png\"\u003e\u003c\/center\u003e\n\n\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-sm-12 text-center text-muted\"\u003e\n\u003ch3\u003e Get to know the Epcom Power Line® UPS Line \u003c\/h3\u003e\n\u003ccenter\u003e\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_img2.png\" width=\"400px\"\u003e\u003c\/center\u003e\n\u003cul\u003e  \u003cli\u003eThe Epcom Power Line® UPS line was designed for high performance and excellent quality\u0026amp;comma; They are used to protect and energize equipment\u0026amp;comma; It also supplies pure voltage with automatic voltage regulator (AVR) in boost and buck. They are simple\u0026amp;comma; at low cost and its installation is simple and quick.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-sm-12 text-center text-muted\"\u003e\u003ccenter\u003e\n\u003ch2\u003e UPS Interactive Line \u003c\/h2\u003e\n\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_3.png\" width=\"350px\"\u003e\u003cp\u003e Epcom Power Line ® interactive UPS are special to meet needs such as networking hardware\u0026amp;comma; computers\u0026amp;comma; etc\u0026amp;comma; These devices correct minor power fluctuations without having to switch to battery mode\u0026amp;comma; making the battery life longer.\u003c\/p\u003e\n\u003c\/center\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-sm-12 text-center text-muted\"\u003e\u003ccenter\u003e\n\u003ch2\u003eUPS On-Line \u003c\/h2\u003e\n\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_img1.png\" width=\"400px\"\u003e\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_icono1.png\" width=\"300px\"\u003e\u003ch4\u003e Reliable Power for your Equipment\u003c\/h4\u003e\n\u003cp\u003e On-Line UPS technology (double conversion) is the high-density version of Epcom Power Line®\u0026amp;comma; It is designed for 100\/110\/115\/120\/127 VAC voltage applications.\u003c\/p\u003e  \u003cp\u003eIt is equipped with power factor correction (PFC) at the input, power factor of 0.9 at the output\u0026amp;comma; offering high levels of reliability and protection for IT systems\u0026amp;comma; telecommunications equipment\u0026amp;comma; mission-critical medical equipment and systems. It is convertible to Rack or Tower and only takes 2U Rack units.\u003c\/p\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/center\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-6 text-muted\"\u003e\n\u003ch3\u003e Highlights\u003c\/h3\u003e\n\u003col style=\"list-style: none;\"\u003e\n\u003cli\u003e • On-Line UPS offer high-efficiency dual-line conversion technology.\u003c\/li\u003e\n\u003cli\u003e • Pure sine wave.\u003c\/li\u003e\n\u003cli\u003e • Operation in Eco mode for energy savings.\u003c\/li\u003e\n\u003cli\u003e • Dynamic voltage range.\u003c\/li\u003e\n\u003cli\u003e • Configurable output voltage via LCD.\u003c\/li\u003e\n\u003cli\u003e • Battery module to extend backup time.\u003c\/li\u003e\n\u003cli\u003e • Rack\/Tower Installation.\u003c\/li\u003e\n\u003cli\u003e • Online topology UPS can be configured horizontally or vertically. \u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-6\"\u003e\u003cimg class=\"img-responsive\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/ftp\/single_page\/epcom_powerline\/ups_5.png\" width=\"400px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-12 col-md-6 text-center text-muted\"\u003e\n\n\u003chr\u003e\n\u003ch2\u003e Dynamic Voltage Range (AVR)\u003c\/h2\u003e  \u003cp\u003eThe Dynamic Voltage Range (AVR) on Epcom Power Line® UPSs helps stabilize the incoming AC signal\u0026amp;comma; is responsible for controlling high and low voltages\u0026amp;comma; maintaining the output power at a nominal level of 120v\u0026amp;comma; reduces system crashes and significantly increases battery life.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-sm-12 col-md-6 text-center text-muted\"\u003e\n\n\u003chr\u003e\n\u003ch2\u003e Configurable output voltages\u003c\/h2\u003e\n\u003cp\u003e Some Epcom Power Line® models\u0026amp;comma; They can be congurable with selectable output voltage: 100 V \/ 110 V \/ 115 V \/ 120 V \/ 127 V AC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e","brand":"EPCOM POWERLINE","offers":[{"title":"Default Title","offer_id":44877058048245,"sku":"EPU2000RTOL2U","price":12793.52,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/EPU2000RTOL2U-h.png?v=1722053995","url":"https:\/\/prolink.mx\/en\/products\/ups-de-2000va-1800w-topologia-on-line-doble-conversion-entrada-y-salida-de-120-vca-clavija-de-entrada-nema-5-20p-pantalla-lcd-configurable-formato-rack-torre","provider":"ProLink","version":"1.0","type":"link"}