{"product_id":"controlador-maestro-para-control-de-elevadores-control-de-acceso-para-los-pisos-de-los-elevadores-por-huella-o-tarjeta-programacion-por-ivms4200-o-interfaz-web","title":"MASTER Controller for Elevator Control \/ Access Control for Elevator Floors by Fingerprint or Card \/ Programming by IVMS4200 or Web Interface ","description":"\u003cdiv\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg class=\"fr-fic fr-dii\" style=\"width: 506px; height: 155px; display: block; margin-left: auto; margin-right: auto;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/jdelafuente\/HIKVISION\/hikvision%20logo%20complete.png\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #ff0000; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eMain features:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e Supports permissions up to 128 floors.\u003c\/li\u003e\n\u003cli\u003e TCP\/IP communication.\u003c\/li\u003e\n\u003cli\u003e Supports up to 2 Wiegand or RS-485 card readers\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eSupports up to 20,000 cards.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003e(Does not support password access)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Input Interface: 1 Panic Button, a fire alarm button\u0026amp;comma; 1 conservation button.\u003c\/li\u003e\n\u003cli style=\"box-sizing: border-box; line-height: 2;\"\u003e \u003cstrong style=\"box-sizing: border-box;\"\u003eWarranty: 2 Years.\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #ff0000; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and Electrical Characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e Operating voltage: 12VD (Power not included)\u003c\/li\u003e\n\u003cli\u003e Operating temperature: -4°C to 70°C (40°F to 158°F)\u003c\/li\u003e\n\u003cli\u003e Dimensions: 167 (L)mm *105 (W)mm *30 (H) mm\u003c\/li\u003e\n\u003cli\u003e 5 relay outputs (For linking, not for floor control)\u003c\/li\u003e  \u003cli\u003eSupports up to a maximum of 24 slave distributors which can control up to 16 floors each ( \u003ca style=\"box-sizing: border-box; background-color: #ffffff; color: #005cb9; outline: 0px; font-size: 12px; font-weight: 600; font-family: 'Open Sans'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=DS-K2M0016A-HIKVISION-163616\u0026amp;autodetect=elevadores\"\u003eDS-K2M0016A\u003c\/a\u003e ) \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #ff0000; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eFeatured Features:\u003c\/strong\u003e\u003cp\u003e HIKVISION elevator controller comprises main elevator controllers (Master) and distributed elevator controllers (Slaves). It can be applied to buildings\u0026amp;comma; public areas\u0026amp;comma; hotels\u0026amp;comma; corporate etc. \u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\u003cdiv class=\"col-sm-12\"\u003e\u003cdiv style=\"border-left: 5px solid #ff0000; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cspan style=\"font-family: verdana\u0026amp;comma; geneva\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eConsiderations:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\u003cli\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eThis model \u003cstrong\u003eis only the master controller\u003c\/strong\u003e \u0026amp;comma; To control the floors, the \u003ca style=\"box-sizing: border-box; background-color: #ffffff; color: #005cb9; outline: 0px; font-size: 12px; font-weight: 600; font-family: 'Open Sans'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=DS-K2M0016A-HIKVISION-163616\u0026amp;autodetect=elevadores\"\u003eDS-K2M0016A\u003c\/a\u003e distributor is required for each 16 floors to be controlled. \u003c\/p\u003e\n\u003cdiv class=\"col-sm-6\" style=\"float: left; text-align: center;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BancoFotografiasSyscom\/HIKVISION\/DSK2M0016A\/DSK2M0016A-p.PNG\" width=\"480\" height=\"480\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-6\" style=\"float: left;\"\u003e\n\u003ch2\u003e Slave Distributor REQUIRED\u003c\/h2\u003e\n\u003cp\u003e Model: \u003ca style=\"box-sizing: border-box; background-color: #ffffff; color: #005cb9; outline: 0px; font-size: 12px; font-weight: 600; font-family: 'Open Sans'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=DS-K2M0016A-HIKVISION-163616\u0026amp;autodetect=elevadores\"\u003eDS-K2M0016A\u003c\/a\u003e\u003c\/p\u003e\n\u003cul style=\"list-style-type: circle;\"\u003e\n\u003cli\u003e\n\n \u003cstrong\u003eUp to 24 slave distributors\u003c\/strong\u003e with 16 floors to control for each one.\u003c\/li\u003e\n\u003cli\u003e \n\u003cstrong\u003eManage permissions to different people\u003c\/strong\u003e \u0026amp;comma; enabling only the floor to which that person can go (they have to swipe their fingerprint or card for the floor corresponding to their access level to be enabled).\u003c\/li\u003e\n\u003cli\u003e\n\n \u003cstrong\u003eZero complications\u003c\/strong\u003e since it is not necessary to interact with the main control panel of the elevator but rather\u0026amp;comma; An interconnection is made with the elevator button panel (using the slave distributor relays \u003ca style=\"box-sizing: border-box; background-color: #ffffff; color: #005cb9; outline: 0px; font-size: 12px; font-weight: 600; font-family: 'Open Sans'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=DS-K2M0016A-HIKVISION-163616\u0026amp;autodetect=elevadores\"\u003eDS-K2M0016A\u003c\/a\u003e )\u0026amp;comma; in such a way that when there is correct access then the button panel is enabled (only the buttons to which the person has access).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eIn your project you must consider the following \u003cspan style=\"color: #c0392b;\"\u003e\u003cstrong\u003efor each Elevator cabin:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e 1 x \u003ca style=\"box-sizing: border-box; background-color: #ffffff; color: #005cb9; text-decoration-line: none; font-size: 12px; font-weight: 600; font-family: 'Open Sans'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=DS-K2210-HIKVISION-163615\u0026amp;autodetect=DS-K2M0016A\"\u003eDS-K2210\u003c\/a\u003e \u003cstrong\u003emaster\u003c\/strong\u003e controller.\n\n\u003c\/li\u003e\n\u003cli\u003e 1 \u003cstrong\u003eslave controller \u003ca style=\"box-sizing: border-box; background-color: #ffffff; color: #005cb9; outline: 0px; font-size: 12px; font-weight: 600; font-family: 'Open Sans'\u0026amp;comma; Helvetica\u0026amp;comma; Arial\u0026amp;comma; sans-serif;\" href=\"https:\/\/www.syscom.mx\/principal\/searchcont?route=DS-K2M0016A-HIKVISION-163616\u0026amp;autodetect=elevadores\"\u003eDS-K2M0016A\u003c\/a\u003e\u003c\/strong\u003e (at least 1\u0026amp;comma; depends on the number of floors).\u003c\/li\u003e  \u003cli\u003e1 Wiegand \/ RS485 reader (for example a DS-K1T671M facial).\u003c\/li\u003e\n\u003cli\u003e The administration is by IVMS4200 ( \u003cstrong\u003esupports up to 2 elevator cabins\u003c\/strong\u003e \u003cstrong\u003emaximum).\u003c\/strong\u003e To control more than 2 elevator cabins, the HikCentral software is necessary.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e Hikvision elevator solution demonstration with real elevator button panel \u003c\/h2\u003e\n\u003cdiv class=\"embed-responsive embed-responsive-16by9\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/9z87vSCJ6Xg\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e","brand":"HIKVISION","offers":[{"title":"Default Title","offer_id":44879443853557,"sku":"DS-K2210","price":4503.54,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/DSK2210-h.png?v=1722075179","url":"https:\/\/prolink.mx\/en\/products\/controlador-maestro-para-control-de-elevadores-control-de-acceso-para-los-pisos-de-los-elevadores-por-huella-o-tarjeta-programacion-por-ivms4200-o-interfaz-web","provider":"ProLink","version":"1.0","type":"link"}