{"title":"All","description":null,"products":[{"product_id":"fuente-extensora-de-circuitos-nac","title":"NAC circuit extender source","description":"\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003cbr\u003e\u0026bull; Input power 120VAC 60Hz \u0026amp; comma; 5 amp.\u003cbr\u003e\u0026bull; Of the (2) Clase A \u0026amp; comma circuits; Z style o of the (2) Clase B \u0026amp; comma circuits;\u003cbr\u003eW \u0026amp; comma; Y style. FACP tickets.\u003cbr\u003e\u0026bull; Two (2) Dry contact NC shooting inputs (Triggers).\u003cbr\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003cbr\u003e\u0026bull; Limited nominal power outputs Class 2.\u003cbr\u003e\u0026bull; 24VDC @ 10 amps of maximum total alarm current.\u003cbr\u003e\u0026bull; Maximum current of 2 \u0026amp; comma;5 A per output.\u003cbr\u003e\u0026bull; 1 \u0026amp; comma;0 amp separate auxiliary output.\u003cbr\u003e\u0026bull; Programmable supervised signaling circuit outputs:\u003cbr\u003eFour (4) Class B \u0026amp; comma; Style W \u0026amp; comma; Y or Two (2) Class A \u0026amp; comma; Style Z or One (1) Class A \u0026amp; comma; Style Z and Two (2) Class B \u0026amp; comma; Style W \u0026amp; comma; Y.\u003cbr\u003e\u0026bull; Thermal and short-circuit protection with automatic rearmament.\u003cbr\u003e\u003cstrong\u003eReserve Battery:\u003c\/strong\u003e\u003cbr\u003e\u0026bull; Embedded loader for batteries sealed with plum acid gel.\u003cbr\u003e\u0026bull; Automatic switch to backup battery when AC fails.\u003cbr\u003e\u0026bull; Zero voltage drop when switching to backup battery.\u003cbr\u003e\u003cstrong\u003eSupervision:\u003c\/strong\u003e\u003cbr\u003e\u0026bull; AC fault monitoring (Contact C \u0026amp; Comma; 1 amp \/ 28VDC).\u003cbr\u003eFactory adjustment for 30 seconds with 2\u0026amp;comma;5 to 3 hours\u003cbr\u003eDelay adjustment (selectable field).\u003cbr\u003e\u0026bull; Immediate local CA problem reporting relay\u003cbr\u003e(Contact form \"C\" \u0026amp; comma; 1 amp \/ 28VDC).\u003cbr\u003e\u0026bull; Battery presence and low battery supervision\u003cbr\u003e(Contact form \"C\" \u0026amp; comma; 1 amp \/ 28VDC).\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e\u003cem\u003e** Product upon request.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ALTRONIX","offers":[{"title":"Default Title","offer_id":44874369106165,"sku":"AL1002ULADA","price":11719.33,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/AL1002ULADA-h.png?v=1722034431"},{"product_id":"gabinete-para-dos-baterias-de-respaldo-de-26-ah-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-fas","title":"Cabinet for two 26 AH backup batteries. For applications in fire detection systems (FAS).","description":"Cabinet for two 26 AH backup batteries.\u003cbr\u003e Dimensions: 39.62 cm x 13.02 cm x 39.37 cm\u003cbr\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877852967157,"sku":"BB-26","price":3059.88,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_a04f723b-d401-4423-a511-94a2eec1cb49.png?v=1785212764"},{"product_id":"gabinete-para-dos-baterias-de-respaldo-de-18-ah-aplicaciones-para-sistemas-de-deteccion-de-incendio-fas","title":"Cabinet for two 18 AH backup batteries. Applications for fire detection systems (FAS).","description":"\u003cp\u003e Cabinet for two 18 AH backup batteries.\u003cbr\u003e Dimensions: 37.38 cm x 12.07 cm x 21.59 cm\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877854507253,"sku":"BB17","price":1820.15,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_ba6a3659-48eb-43b1-ba19-8adcd07cc6b8.png?v=1785212768"},{"product_id":"estacion-manual-de-emergencia-direccionable","title":"Addressable Manual Emergency Station","description":"\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BG12L\/82169-firelite_copia.jpg\" alt=\"\" width=\"700\" height=\"366\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eFire-Lite's BG-12LX Emergency Manual Station allows the control panel to display the exact trigger point location thanks to its built-in addressing\u0026amp;comma; also\u0026amp;comma; It considerably reduces false alarms due to accidental activation since it requires two movements for activation\u0026amp;comma; Used exclusively with MS-9050UD addressable fire detection panels\u0026amp;comma; MS-9200UDLS\u0026amp;comma; MS-9600UDLS and the new Endurance ES50X series\u0026amp;comma; ES50XI\u0026amp;comma; ES200 and ES200XI.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e  \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eUL Listed, ULC\u0026amp;comma; MEA\u0026amp;comma; FM and CSFM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eVisible and elegant design and color\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eDual drive, designed to prevent false alarms due to accidental activation\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eWhen activated\u0026amp;comma; the lever locks to indicate that the station has been operated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eLock with key\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThe station can be opened for inspection and maintenance without initiating an alarm\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCan be mounted in an SB-10 box or in a conventional electrical box\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003ePower: 24 Vdc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eConsumption: 5 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eDimensions: 139 x 104 x 35mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/BG12LX\/82158-comparativa_bg12l.jpg\" alt=\"\" width=\"843\" height=\"292\"\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877858603253,"sku":"BG-12LX","price":1860.7,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_4e8ce6e5-987c-4302-bac5-77d742f24c51.png?v=1785119774"},{"product_id":"modulo-de-salida-de-notificacion","title":"Notification Output Module ","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/CMF300\/82161-cmf300_p2rl.jpg\" alt=\"\" width=\"651\" height=\"200\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThe Fire-Lite CMF-300 Addressable Control Module provides a Class B or Class A supervised circuit for notification appliances (horns, strobes, etc.). Addressability allows the CMF to be activated through panel programming.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e \u003c\/span\u003e \u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eUL Listed, ULC\u0026amp;comma; MEA\u0026amp;comma; FM and CSFM\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eCan be used to switch power to 24 volt NACs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eAn external power supply trouble condition will never interfere with the rest of the system\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eAutomatically identifies itself on the control panel\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003ePower: 24 Vdc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eMaximum load capacity up to 3-amp\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eConsumption: 6.5 mA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eDimensions: 114 x 101 x 31mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877860569333,"sku":"CMF-300","price":1462.9,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S400_cf4aa263-f17b-4d58-ac5f-20eae9476b0a.png?v=1786328151"},{"product_id":"modulo-aislador-de-fallas-corto-circuito-para-lazo-slc","title":"Fault Isolator Module - Short Circuit for SLC Loop","description":"\u003cp\u003e Fire-Lite I300 Isolator Module is used with MS-9050UD panels\u0026amp;comma; MS-9200UDLS\u0026amp;comma; MS-9600UDLS and Fire-Lite ES50X Endurance Series\u0026amp;comma; ES50XI\u0026amp;comma; ES200X and ES200XI to protect the system from wire-to-wire short circuits in the SLC loop. It must be located between each device in the SLC loop\u0026amp;comma; to isolate a short circuit problem between devices.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eUL Listed, ULC\u0026amp;comma; MEA\u0026amp;comma; FM and CSFM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Generally used in each T-branch to limit the effect of short circuits\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eIsolates devices so they can continue to function normally in the event of a short circuit\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Powered directly by SLC loop\u0026amp;comma; requires no external power.\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eMounts to standard electrical boxes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Power: 24 Vdc\u003c\/li\u003e\n\u003cli\u003e Consumption: 0.45 mA\u003c\/li\u003e  \u003cli\u003eDimensions: 114 x 114 x 6mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877862469877,"sku":"I300","price":1187.41,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_95679535-31e3-4f37-a8e2-c37489565df7.png?v=1785212784"},{"product_id":"modulo-monitor-dual-monitorea-2-contactos-secos-agrega-sensores-convencionales-al-slc","title":"Dual Monitor Module - Monitors 2 Dry Contacts, Adds Conventional Sensors To SLC.","description":"\u003cp\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/MDF300\/82728-mdf-300.jpg\" alt=\"\" width=\"651\" height=\"200\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThe MDF-300 is a dual addressable monitoring module that suits a wide variety of applications. It is used to monitor two initialization device circuits (IDC) such as; temperature detectors\u0026amp;comma; smoke detectors\u0026amp;comma; manual stations\u0026amp;comma; gas detectors\u0026amp;comma; flow sensors, pressure sensors, etc Used exclusively with MS-9050UD addressable fire detection panels\u0026amp;comma; MS-9200UDLS\u0026amp;comma; MS-9600UDLS and Fire-Lite ES50X Endurance Series\u0026amp;comma; ES50XI\u0026amp;comma; ES200X and ES200XI.\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e  \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eUL Listed, ULC\u0026amp;comma; MEA\u0026amp;comma; FM and CSFM\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eMonitor and supervise two Class A or Class B initialization device circuits (IDCs)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eTwo separate consecutive addresses\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eAutomatically identifies itself on the control panel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003ePower: 24 Vdc\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eConsumption: 6.4 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eDimensions: 114 x 101 x 31mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877862764789,"sku":"MDF-300","price":2445.94,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_5d7f9665-797f-4e41-aeaf-d89525e946bc.png?v=1785119777"},{"product_id":"detector-de-humo-por-haz-reflejado-direccionable-compatible-con-paneles-direccionables-fire-lite","title":"Reflected Beam Smoke Detector \/ Addressable \/ Compatible with Fire-Lite Addressable Panels","description":"\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThe OSI-RI-FL is an intelligent addressable reflector type linear optical beam smoke detector. It is especially suitable for protecting large open areas with high ceilings\u0026amp;comma; where spot-type smoke detectors are difficult to install and maintain. Ideal applications include warehouses, atriums\u0026amp;comma; aircraft suspensions\u0026amp;comma; sports stadiums and concert halls. The beam mainly operates on the principle of light dimming using infrared. The OSI-RI-FL detector is a combo transmitter\/receiver that can be connected directly to a smart detector circuit in LiteSpeed® or CLIP mode.\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eOSI-RI-FLs are limited to the amount of current that a Fire-Lite panel can deliver. A detector in standby can consume up to 20mA and in Alarm 22ma. This limits any Fire-Lite panel to using 5 detectors per Loop. Obviously the number of detectors can range between 4 and 5 depending on the wiring conditions. In optimal cabling, it cannot exceed 5 OSIRIFL devices per Loop.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eCharacteristics:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Combined transmitter\/receiver unit\u003c\/span\u003e \u003cbr\u003e\u003cspan style=\"font-family: 'Arial'\u0026amp;comma;sans-serif; color: #222222; background: white;\"\u003e• Paintable housing\/lid\u003c\/span\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Wide 12° field of view\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Fast beam alignment\u0026amp;comma; easy and intuitive indicated by directional\u003c\/span\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003eLED arrows\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Long range coverage of 16-328 feet (5-100 m) is standard; no separate long range kit required\u003c\/span\u003e\u003c\/span\u003e \u003cbr\u003e\u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Highly resistant to building movement; tolerates +\/- 1° movement\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Resistant to strong light sources; does not alarm when saturated\u003c\/span\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003eby sunlight\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Resistant to the intrusion of solid objects.\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Automatic sensitivity threshold level adjustments and drift compensation\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• 50° horizontal and 20° vertical beam adjustment\u003c\/span\u003e \u003cbr\u003e\u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Built-in image heater\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Remote test station capable of electronically simulated smoke testing\u003c\/span\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003efrom ground level\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• LED status indicators visible from the front and bottom\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Pluggable removable terminal blocks\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003e• Optional heater kit available for reflector\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003eSpecifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"background-color: white; color: #222222; font-family: Arial\u0026amp;comma; sans-serif;\"\u003eOperating Voltage: Nominal 24VDC\u003cbr\u003e Maximum 32 VDC\u003cbr\u003e Minimum 15 VDC\u003cbr\u003e Maximum standby current:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e13 mA @ 32 VDC\u003c\/span\u003e\u003cbr\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e14 mA @ 24 VDC\u003cbr\u003e 20 mA @ 15 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eMaximum current in alarm:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e22 mA @ 32 VDC\u003cbr\u003e 15mA @ 24VDC\u003cbr\u003e 22 mA @ 15 VDC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e \u003cstrong\u003eComparison OSIRIFL vs OSID\u003c\/strong\u003e \u003c\/h2\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: .0001pt;\"\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/OSIRIFL\/170947-osrivs.png\" alt=\"Comparison OSID vs OSIRIFL\" width=\"955\" height=\"486\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch2\u003e \u003cstrong\u003eAlignment steps\u003c\/strong\u003e \u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/OSIRIFL\/170947-pasos.png\" alt=\"Steps\" width=\"1018\" height=\"430\"\u003e\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877863026933,"sku":"OSI-RI-FL","price":18372.08,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_2161554f-2c0b-4d9d-a903-256c3c936e02.png?v=1785212789"},{"product_id":"detector-de-humo-fotoelectrico-direccionable-con-prueba-remota-para-ducto-color-marfil","title":"Addressable photoelectric smoke detector with remote testing for duct, ivory color.","description":"\u003cp\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt;\"\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThe SD365R and SD365R-IV models are plug-in smoke sensors that combine a photo-electronic detection camera with addressable analog communications. When used in duct applications with a DNR (W)\u0026amp;comma; Testing can be performed remotely using System Sensor approved test accessories. The sensors transmit an analog representation of the smoke density over a communication line to a control panel. Includes rotary switch for device addressing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt;\"\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eCharacteristics\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\" style=\"margin-bottom: 0.0001pt;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eListings and approvals: UL\u0026amp;comma; ULC\u0026amp;comma; FM and CSFM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eNew modern profile\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eAnalog communications\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eLow current consumption\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eRotary direction switches\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eDual LEDs for 360° visibility\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eColor options including white and ivory\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eDoes not include base\u0026amp;comma; sold separately (special duct base) DNR (W)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eSpecifications\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cspan lang=\"EN-US\"\u003eOperating Voltage Range: 15 to 32 VDC\u003c\/span\u003e\u003c\/span\u003e \u003cbr\u003e\u003cspan lang=\"EN-US\"\u003eOperating Current @ 24 VDC: 200 uA (one communication every 5 seconds with green LED blink on communication)\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eMaximum Alarm Current: 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on)\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eMaximum Current: 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on)\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eOperating Humidity Range: 10% to 93% Relative Humidity\u0026amp;comma; Non-condensing\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eOperating Temperature Range: 32°F to 122°F (0°C to 50°C)\u0026amp;comma; -4°F to 158°F (-20°C to 70°C) in duct applications\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eAir Velocity: 0 to 4000 ft.\/min. (0 to 1219.2 m\/min.)\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eHeight: 2.0˝ (51 mm) installed in B300-6 Base\u003cbr\u003e\u003c\/span\u003e \u003cspan lang=\"EN-US\"\u003eDiameter: 6.2˝ (156 mm) installed in B300-6 Base; 4.1˝ (104 mm) installed in B501 Base\u003cbr\u003e\u003c\/span\u003e Weight: 3.4 oz. (95g)\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877866631413,"sku":"SD365R-IV","price":2480.44,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_84e36972-2f54-4b05-9879-f076e53043fd.png?v=1785292374"},{"product_id":"expansor-de-lazo-para-panel-ms-9600udls-habilita-318-dispositivos","title":"Loop Expander for MS-9600UDLS Panel. Enable 318 devices.","description":"\u003cp\u003e \u003cbr\u003eThis Expander module provides a second SLC loop for the MS-9600UDLS control panel. This makes it possible to connect 318 additional addressable devices\u0026amp;comma; which makes the number of addressable devices that can be connected to the panel 636. Of which 318 will be modules and 318 devices.\u003cbr\u003e For information on connecting devices to the SLC\u0026amp;comma; Consult the panel installation manual.\u003cbr\u003e\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44877866991861,"sku":"SLC-2LS","price":9020.54,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_59bfbf70-11c3-4532-b86e-2776760bb7a1.png?v=1785212800"},{"product_id":"alarma-de-monoxido-de-carbono-co-operada-por-baterias-con-display-digital","title":"Battery-operated carbon monoxide (CO) alarm with digital display","description":"\u003cp style=\"text-align: justify;\"\u003eReceive alerts about dangerous carbon monoxide leaks with the First Alert CO410 Battery Operated Carbon Monoxide Alarm with Backlit Digital Display. This carbon monoxide detector uses an electrochemical carbon monoxide sensor. An easy-to-read backlit digital display allows for a quick view of current and maximum CO levels. This detector runs on two replaceable AA batteries, offering peace of mind even during power outages.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877867122933,"sku":"1039727","price":1010.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/1039727-h_621bff47-6a67-470b-893f-c7cd54013951.png?v=1722063539"},{"product_id":"alarma-de-monoxido-de-carbono-co-enchufable-con-bateria-de-respaldo","title":"Plug-in carbon monoxide (CO) alarm with battery backup","description":"\u003cp style=\"text-align: justify;\"\u003eThe First Alert CO600 plug-in carbon monoxide alarm uses an electrochemical carbon monoxide sensor. This carbon monoxide detector plugs into any standard electrical outlet and features an end-of-life warning to let you know when you need to replace the alarm. When carbon monoxide levels rise\u0026amp;comma; A loud 85-decibel alarm alerts you to the threat.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877867548917,"sku":"1039730","price":589.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/1039730-h_d51d4048-c34e-41e9-8588-2761a4a26f32.png?v=1722063539"},{"product_id":"alarma-de-monoxido-de-carbono-co-enchufable-con-bateria-de-respaldo-y-display-digital","title":"Plug-in carbon monoxide (CO) alarm with backup battery and digital display","description":"\u003cp style=\"text-align: justify;\"\u003eThe First Alert CO615 Dual Power Plug-In Carbon Monoxide Alarm alerts you to dangerous levels of carbon monoxide. This plug-in carbon monoxide detector operates on a dual power system with battery backup for continuous monitoring\u0026amp;comma; even in the event of a power outage. The backlit digital display tells you the carbon monoxide and power levels at a glance. The CO alarm also features a convenient test and silence button and an end-of-life warning that lets you know when it's time to replace the alarm.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877867647221,"sku":"1039746","price":1128.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/1039746-h_d998908e-307c-4fe6-a0db-e850c0591e92.png?v=1722063543"},{"product_id":"alarma-de-monoxido-de-carbono-co-con-bateria-de-10-anos-y-display-digital-de-temperatura","title":"Carbon monoxide (CO) alarm with 10-year battery and digital temperature display","description":"\u003cp style=\"text-align: justify;\"\u003eThe First Alert CO710 Carbon Monoxide Alarm with 10-Year Battery and Digital Temperature Display detects dangerous carbon monoxide for up to 10 years. This carbon monoxide detector uses an electrochemical carbon monoxide sensor. A built-in 10-year lithium battery means you don't need to worry about changing batteries over the life of the alarm. This stylish CO monitor is designed to sit on a dresser or table and has a backlit digital display that shows temperature and CO concentration.\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877867942133,"sku":"1039753","price":1192.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/1039753-h_8650337c-4d20-411a-bea7-8369940915c3.png?v=1722063541"},{"product_id":"detector-combo-de-humo-co-autonomo-no-requiere-panel-diseno-ultra-delgado-no-requiere-cableado","title":"Combo Smoke\/CO Detector, Standalone, No Panel Required, Ultra Slim Design, No Wiring Required","description":"\u003cp\u003e Combo Smoke\/CO Detector Autonomous\u0026amp;comma; No Panel Required\u0026amp;comma; Ultra Slim Design: No Wiring Required\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eLow profile photoelectric combined carbon monoxide and smoke alarm\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eThe First Alert PRC700 smoke and carbon monoxide detector has a slim profile, Designed to blend better into the wall and out of sight. It offers the same functionality you expect from First Alert with a new design that takes up less space. The battery-operated smoke and carbon monoxide detector warns you of possible fumes or carbon monoxide and can be installed anywhere, without the need for cables.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eSlim profile is ideal for modern decor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eFirst Alert's combined photoelectric and carbon monoxide smoke detector is half the thickness of traditional detection devices\u0026amp;comma; while offering reliable smoke and carbon monoxide detection. Slim design blends more easily with walls and ceilings\u0026amp;comma; ensuring that safety does not interfere with style. The sleek white dial minimizes the usual lights and buttons on regular detectors for a cleaner look.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eComprehensive detection for your home or office\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eA photoelectric sensor detects smoke from slow fires\u0026amp;comma; while reducing the number of false alarms due to smoke from the kitchen or steam from a shower. Advanced electrochemical sensor detects carbon monoxide leaks from multiple sources, including defective fuel burning appliances. The combination of smoke and CO detectors provides monitoring for both conditions in one streamlined device.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eBattery operation eliminates cables\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e The photoelectric smoke and carbon monoxide combination alarm is powered by two AA batteries. eliminating the need for wiring or installation by an electrician. It can be mounted anywhere, on ceilings and walls. Battery operation means that even in the event of a power outage, The alarm can continue to work.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e PRODUCT DETAILS\u003c\/p\u003e\n\u003cp\u003e Power supply: battery powered\u003c\/p\u003e\n\u003cp\u003e Battery type: two AA\u003c\/p\u003e  \u003cp\u003eSensor: photoelectric and electrochemical\u003c\/p\u003e\n\u003cp\u003e Optipath 360° Technology: Patented technology provides 360° direct access to the smoke sensor\u003c\/p\u003e\n\u003cp\u003e Smart Detection Technology – Helps reduce nuisance alarms\u003c\/p\u003e\n\u003cp\u003e Noise output: 85 dB in a T3 pattern\u003c\/p\u003e\n\u003cp\u003e Single button: one press to silence and test the alarm\u003c\/p\u003e\n\u003cp\u003e Low profile design – half the thickness of a standard alarm\u003c\/p\u003e\n\u003cp\u003e Perfect Mount: The mounting bracket keeps the alarm secure in a wide range of rotation to allow for perfect alignment.\u003c\/p\u003e\n\u003cp\u003e Tamper Resistant - Includes Locking Pins\u003c\/p\u003e\n\u003cp\u003e Optional locking feature – secures alarm to mounting bracket\u003c\/p\u003e\n\u003cp\u003e Standards: UL 217 and UL 2034\u003c\/p\u003e\n\u003cp\u003e Warranty: 7 years limited\u003c\/p\u003e\n\u003cp\u003e Product Dimensions (L x W x H): 5'67 x 1 x 5'67 in.\u003c\/p\u003e\n\u003cp\u003e Product weight: 0:55 lbs.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch2 style=\"text-align: center;\"\u003e Combo Smoke and Carbon Monoxide Detector\u003c\/h2\u003e\n\u003ch2 style=\"text-align: center;\"\u003e Super Slim Design Fully Autonomous \u003c\/h2\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/UyqYy6zHtRc\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/timGBRCsmGU\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877869613301,"sku":"1039783","price":851.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/1039783-h.png?v=1722063544"},{"product_id":"detector-combo-de-humo-co-autonomo-bateria-sellada-de-litio-de-10-anos-no-requiere-panel-diseno-ultra-delgado-no-requiere-cableado","title":"Combo Smoke\/CO Detector, Self-Contained, 10-Year Sealed Lithium Battery, No Panel Required, Ultra Slim Design, No Wiring Required","description":"\u003cp\u003e 10 year sealed battery combination alarm\u003c\/p\u003e  \u003cp\u003eThe First Alert PRC710 Slim Photoelectric Smoke and Carbon Monoxide Alarm with 10-Year Battery helps protect your home from two life-threatening threats by providing up to a decade of uninterrupted monitoring. Equipped with double sensors\u0026amp;comma; This low-profile alarm detects smoke from slow-burning fires. Half the thickness of a standard alarm\u0026amp;comma; This detector has a slim, contemporary design that mounts discreetly to a wall or ceiling. A built-in 10-year lithium-ion battery provides continuous power, no need to worry about changing the battery during the life of the alarm.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Photoelectric sensor warns of latent fires\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eThe First Alert PRC710 alarm comes equipped with a photoelectric sensor to provide the earliest possible fire warning. The sensor is optimized to detect larger smoke particles produced by smoldering fires, such as those caused by unextinguished cigarettes. It also distinguishes between real threats and smoke\/steam produced during the shower\u0026amp;comma; cooking and other daily activities\u0026amp;comma; which helps minimize the number of false alarms. A patented smoke inlet system helps ensure reliable detection by providing a direct air path to the sensor.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Electrochemical sensor monitors CO levels\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eThe alarm also features an advanced electrochemical sensor that detects carbon monoxide leaks from a variety of sources\u0026amp;comma; such as defective appliances\u0026amp;comma; blocked chimneys and running cars in the garage. Carbon monoxide cannot be seen\u0026amp;comma; smell or taste in the air\u0026amp;comma; and is the leading cause of accidental poisoning deaths in the United States. By placing carbon monoxide detectors on every floor of the house and in every bedroom\u0026amp;comma; can help protect your family from the danger of carbon monoxide.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Built-in 10-year battery\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e The First Alert PRC710 10-Year Photoelectric Smoke and Carbon Monoxide Alarm features a built-in 10-year lithium battery that provides continuous power for the life of the detector. An end-of-life timer lets you know when the device needs to be replaced.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Sleek, low profile design\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eHalf the thickness of a standard alarm\u0026amp;comma; The First Alert PRC710 photoelectric smoke and carbon monoxide alarm includes premium detection features in a sleek, compact unit. The ultra-slim design features a white finish that blends seamlessly with most home decor.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Battery powered alarm installs easily\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e This battery-powered smoke and carbon monoxide detector requires no wiring or electrician to install. Simply mount it to a wall or ceiling using the versatile twist-lock mounting bracket. An end-of-life signal will notify you when the detector is about to expire.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e Alerts you to danger\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eWhen a threat is detected\u0026amp;comma; The smoke and carbon monoxide alarm sounds a loud 85-decibel siren that is designed to wake up even the deepest sleepers. A single button allows you to silence alarms and test if the device is working.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e First Alert PRC710 Photoelectric Combination Carbon Monoxide and Smoke Alarm\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e *Meets California 10-year smoke alarm requirements, New York and New Jersey\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e PRODUCT DETAILS\u003c\/p\u003e\n\u003cp\u003e Power supply: battery powered\u003c\/p\u003e\n\u003cp\u003e Battery type: 10-year sealed lithium\u003c\/p\u003e\n\u003cp\u003e Sensor: photoelectric and electrochemical\u003c\/p\u003e\n\u003cp\u003e Optipath 360° Technology: Patented technology provides 360° direct access to the smoke sensor\u003c\/p\u003e\n\u003cp\u003e Smart Detection Technology – Helps reduce nuisance alarms\u003c\/p\u003e\n\u003cp\u003e Noise output: 85 dB in a T3 pattern\u003c\/p\u003e\n\u003cp\u003e Single button: one press to silence and test the alarm\u003c\/p\u003e\n\u003cp\u003e Profile design: half as thick as a standard alarm\u003c\/p\u003e  \u003cp\u003ePerfect Mount: The mounting bracket keeps the alarm secure in a wide range of rotation to allow for perfect alignment.\u003c\/p\u003e\n\u003cp\u003e Tamper Resistant - Includes Locking Pins\u003c\/p\u003e\n\u003cp\u003e Optional locking feature – secures alarm to mounting bracket\u003c\/p\u003e\n\u003cp\u003e Standards: UL 217 and UL 2034\u003c\/p\u003e\n\u003cp\u003e Warranty: 10 years limited\u003c\/p\u003e\n\u003cp\u003e Product Dimensions (L x W x H): 5'67 x 1'13 x 5'67 inches.\u003c\/p\u003e\n\u003cp\u003e Product weight: 0:73 lbs.\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877872005365,"sku":"1039868","price":939.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/1039868-h.png?v=1722063694"},{"product_id":"alarma-de-monoxido-de-carbono-co-operada-por-baterias-1","title":"Battery-operated carbon monoxide (CO) alarm","description":"\u003cp style=\"text-align: justify;\"\u003e The First Alert CO400 carbon monoxide alarm uses an electrochemical carbon monoxide sensor to detect carbon monoxide. This carbon monoxide detector runs on batteries, making it portable and easy to use\u0026amp;comma; even in the event of a power outage. When carbon monoxide levels rise\u0026amp;comma; A loud 85-decibel alarm alerts you to the threat.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877872529653,"sku":"CO400B1","price":547.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/CO400B1-h_4b46b786-5e70-4c9c-a20c-894037784125.png?v=1722063543"},{"product_id":"alarma-de-monoxido-de-carbono-co-interconectada-inalambricamente-con-voz-y-ubicacion-de-la-alerta","title":"Wirelessly interconnected carbon monoxide (CO) alarm with voice and alert location","description":"\u003cp style=\"text-align: justify;\"\u003eThe First Alert CO511B Wireless Interconnected Carbon Monoxide Alarm with Voice and Location detects elevated levels of carbon monoxide and can work with compatible models to create a wireless alert system throughout your home. This battery-powered, wireless-enabled CO detector alerts you with voice alerts including a loud 85-decibel alarm. Interconnected wireless technology allows other compatible First Alert wireless alarms located in separate areas of your home to communicate with each other\u0026amp;comma; alerting you to a problem even when you are on another floor. The carbon monoxide alarm has an electrochemical sensor.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877873086709,"sku":"CO511B","price":1584.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/CO511B-h_9fe309b9-663c-42a2-b4d1-91efb9a97084.png?v=1722063696"},{"product_id":"alarma-de-monoxido-de-carbono-co-enchufable-con-bateria-de-respaldo-1","title":"Plug-in carbon monoxide (CO) alarm with battery backup","description":"\u003cp style=\"text-align: justify;\"\u003eThe First Alert CO400 carbon monoxide alarm uses an electrochemical carbon monoxide sensor to detect carbon monoxide. This carbon monoxide detector runs on batteries, making it portable and easy to use\u0026amp;comma; even in the event of a power outage. When carbon monoxide levels rise\u0026amp;comma; A loud 85-decibel alarm alerts you to the threat.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e","brand":"FIRST ALERT","offers":[{"title":"Default Title","offer_id":44877873217781,"sku":"CO605B","price":660.19,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S400_3c499778-13dc-4d25-94f5-6bb4622ce664.png?v=1789184794"},{"product_id":"cable-interfaz-para-impresora-para-paneles-hochiki-firenet-0100-06570","title":"Printer Interface Cable for Hochiki FireNET Panels (0100-06570)","description":"\u003cp\u003e • Allows you to connect a serial printer to Hochiki FireNET panels\u003cbr\u003e • Compatible with panels: FNP1127DER\u0026amp;comma; FNP1127DEC\u0026amp;comma; FN2127\u0026amp;comma; FN2127C\u0026amp;comma; FN4127 and FN4127C.  \u003cbr\u003e• 3 m in length.\u003c\/p\u003e","brand":"HOCHIKI","offers":[{"title":"Default Title","offer_id":44879584919797,"sku":"FN-P187","price":1141.05,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_d03cbe31-bab4-435d-b2bf-a6923eae31ed.png?v=1789266423"},{"product_id":"detector-de-humo-motorizado-por-haz-reflejado-con-alineacion-automatica-convencional-compatible-con-todos-los-paneles-de-deteccion-de-incendio-0200-11650","title":"Reflected Beam Motorized Smoke Detector with Automatic Alignment \/ Conventional \/ Compatible with All Fire Detection Panels (0200-11650) ","description":"\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv class=\"gmail_default\" style=\"font-family: arial\u0026amp;comma;sans-serif;\"\u003e\n\u003ch1 style=\"font-family: Times; text-align: center;\"\u003e The Beam Detector Aligns Itself!\u003c\/h1\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e The H6011-120 Fireray One offers small warehouses cost-effective protection and easy installation. It is a standalone beam detector with all the benefits of Fireray reflective beam detection with a single point of wiring and commissioning.\u003c\/div\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e For new buildings\u0026amp;comma; while other beam detectors become misaligned and generate nuisance alarms due to building settlement\u0026amp;comma; Fireray One automatically compensates for natural building movement to continually maintain alignment with Building Movement Tracking™\u003c\/div\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e\u003c\/div\u003e  \u003cdiv style=\"font-family: Times;\"\u003eThe Fireray One\u0026amp;comma; without the need for tools or special knowledge for installation and operation\u0026amp;comma; It is a stand-alone beam detector that makes installation easy.\u003c\/div\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"font-family: Times;\"\u003e Auto-Aligment™ in one minute - just point the laser at the reflector and\u0026amp;comma; when you press the switch\u0026amp;comma; aligns. 8 times faster than previous detectors. One person for alignment and installation.\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e \u003cstrong\u003eSome advantages\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Quick coverage, simple and economical warehouse for fire detection.\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e \u003cstrong\u003eSome applications\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003eWarehouses\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Airports\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Train Stations\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Self-service stores\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Cinemas\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Malls\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Theaters\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e Auditoriums\u003c\/div\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e and many more...\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"background-color: #ffffff;\"\u003e \u003cstrong\u003eCharacteristics\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cul style=\"background-color: #ffffff;\"\u003e\n\u003cli\u003e\n\n \u003cstrong\u003eOperating voltage: 14 to 36 VDC\u003c\/strong\u003e .\u003c\/li\u003e\n\u003cli\u003e \n\u003cstrong\u003eIntegrated visible laser\u003c\/strong\u003e \u003cstrong\u003eand automatic alignment for maximum ease of alignment\u003c\/strong\u003e .\u003c\/li\u003e\n\u003cli\u003e Avoid annoying alarms with \u003cstrong\u003eLight Cancellation Technology™\u003c\/strong\u003e that compensates for sunlight and artificial light sources.\u003c\/li\u003e\n\u003cli\u003e\n\n \u003cstrong\u003eBuilding Movement Tracking™\u003c\/strong\u003e continually maintains alignment as buildings settle or flex due to temperature variations.\u003c\/li\u003e\n\u003cli\u003e\n\n \u003cstrong\u003eContamination compensation\u003c\/strong\u003e to correct the gradual accumulation of dust on the optics.\u003c\/li\u003e\n\u003cli\u003e Avoid \u003cstrong\u003einterbeam interference with dynamic beam phasing\u003c\/strong\u003e ; Install beams facing each other or in irregular configurations.\u003c\/li\u003e\n\u003cli\u003e Detection range: 5 to 50m. Kit of 3 long distance prisms \u003cstrong\u003eup to 120 m\u003c\/strong\u003e .\u003c\/li\u003e\n\u003cli\u003e Integrated user interface with alignment mode switch\u0026amp;comma; directional alignment buttons and configuration switches for alarm response threshold.\u003c\/li\u003e  \u003cli\u003e2 green LEDs and 1 yellow LED to indicate alignment status.\u003c\/li\u003e\n\u003cli\u003e System status indication: Green LED for normal operation\u0026amp;comma; Red LED for alarm condition and yellow LED for fault condition (darkening or contamination).\u003c\/li\u003e\n\u003cli\u003e Flat front with closed optics. Cleaning the optics does not affect alignment.\u003c\/li\u003e\n\u003cli\u003e Laser assisted automatic alignment.\u003c\/li\u003e\n\u003cli\u003e Pollution compensation.\u003c\/li\u003e\n\u003cli\u003e Light cancellation technology.\u003c\/li\u003e\n\u003cli\u003e Individual alarm and fault relays 2 A @ 30 VDC.\u003c\/li\u003e\n\u003cli\u003e Single point wiring and commissioning.\u003c\/li\u003e\n\u003cli\u003e Guarantee up to 5 years against manufacturing defects.\u003c\/li\u003e\n\u003cli\u003e IP55 rating.\u003c\/li\u003e\n\u003cli\u003e Polycarbonate UL94 V0\u003c\/li\u003e\n\u003cli\u003e Operating current: 5 mA.\u003c\/li\u003e\n\u003cli\u003e Integrated user interface.\u003c\/li\u003e\n\u003cli\u003e Clean detectors quickly and easily without affecting alignment.\u003c\/li\u003e\n\u003cli\u003e Low energy consumption.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e FIRERAY ONE AUTOMATIC ALIGNMENT MOTORIZED REFLECTIVE BEAM SMOKE DETECTOR\u003c\/p\u003e\n\u003cp\u003e Product Code: \u003cstrong\u003e0200-11650\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cul\u003e  \u003cli\u003eIntegrated visible laser and automatic alignment for maximum ease of alignment\u003c\/li\u003e\n\u003cli\u003e Integrated user interface\u003c\/li\u003e\n\u003cli\u003e Avoid annoying alarms with Light Cancellation Technology™ that compensates for sunlight and artificial light sources\u003c\/li\u003e\n\u003cli\u003e Building Movement Tracking™ continuously maintains alignment as buildings settle or flex due to temperature variations\u003c\/li\u003e\n\u003cli\u003e Contamination compensation to correct gradual dust buildup on optics\u003c\/li\u003e\n\u003cli\u003e Clean detectors quickly and easily without affecting alignment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Low energy consumption\u003c\/p\u003e\n\u003cp\u003e Avoid interbeam interference with dynamic beam phasing; install beams facing each other or in irregular configurations\u003c\/p\u003e\n\u003cp\u003e Detection range up to 393 ft (120 m)\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003ch2 style=\"background-color: #ffffff; text-align: center;\"\u003e Motorized Reflected Beam Smoke Detector with Automatic Alignment \u003c\/h2\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/BqZliw9iSyU?si=--reh9ZqJK2Hyg1o\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003c\/p\u003e\n\u003ch2 style=\"background-color: #ffffff; text-align: center;\"\u003e Automatic Alignment \u003c\/h2\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/w7LE1Prr5s0?si=rZ_WPuDhgKY3jzkO\" width=\"560\" height=\"314\" allowfullscreen=\"allowfullscreen\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"HOCHIKI","offers":[{"title":"Default Title","offer_id":44879585509621,"sku":"H6011-120","price":18782.98,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/H6011120-h.png?v=1722079310"},{"product_id":"modulo-aislador-de-cortocircuito","title":"Short Circuit Isolator Module","description":"\u003cp\u003e \u003cstrong style=\"line-height: 20.7999992370605px;\"\u003e\u003cem\u003e\u003cimg class=\"fr-fic fr-dii\" style=\"width: 400px; height: 40px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/yhermosillo\/SILENT%20KNIGHT\/Frenhyt.png\" alt=\"\"\u003e\u003cbr\u003e IDP Advanced Series of Detectors and Modules\u003c\/em\u003e\u003c\/strong\u003e \u003cstrong style=\"line-height: 20.7999992370605px;\"\u003e\u003cem\u003efor Silent Knight panels\u003c\/em\u003e\u003c\/strong\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e \u003cbr style=\"line-height: 20.7999992370605px;\"\u003e\u003cspan style=\"line-height: 20.7999992370605px;\"\u003eThe Detectors and Modules of the IDP series\u0026amp;comma; are addressable smart devices for use with Silent Knight Analog-Addressable panels. They communicate with the Fire Panel through the Signaling Line Circuit (SLC) using a two-wire connection\u0026amp;comma; no shielded or braided cable required\u0026amp;comma; Up to 99 detectors and 99 modules can be connected per loop (the IFP2000 panel can have up to 159 detectors and 159 modules per loop). Any combination of IDP addressable devices can be used on a single SLC loop.\u003c\/span\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e \u003cspan style=\"line-height: 20.7999992370605px;\"\u003e• Isolates short circuits in the SLC loop\u003cbr\u003e \u003cstrong\u003e• Protects the SLC loop so that other devices continue to function\u003c\/strong\u003e\u003c\/span\u003e \u003cbr style=\"line-height: 20.7999992370605px;\"\u003e\u003cspan style=\"line-height: 20.7999992370605px;\"\u003e•\u003c\/span\u003e \u003cspan style=\"line-height: 20.7999992370605px;\"\u003eStatus LED: Green in normal state and Red in alarm\u003c\/span\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e \u003cspan style=\"line-height: 20.7999992370605px;\"\u003e• Fully supervised\u003c\/span\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e \u003cspan style=\"line-height: 20.7999992370605px;\"\u003e•\u003c\/span\u003e \u003cstrong style=\"line-height: 20.7999992370605px;\"\u003eUL Listed\u003c\/strong\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e\u003cbr style=\"line-height: 20.7999992370605px;\"\u003e \u003cstrong style=\"line-height: 20.7999992370605px;\"\u003eImportant Note: The IDP series is only compatible with IFP1000 or IFP2000 panels\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL FARENHYT SERIES","offers":[{"title":"Default Title","offer_id":44879616377077,"sku":"IDPISO","price":1595.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/IDPISO-h.png?v=1722079887"},{"product_id":"panel-de-deteccion-de-incendio-direccionable-hasta-2100-puntos-en-cualquier-combinacion-compatible-con-protocolos-idp-sk-y-sd","title":"Fire Detection Panel \/ Addressable \/ Up to 2100 Points in Any Combination \/ Compatible with IDP, SK and SD Protocols ","description":"\u003cp\u003e\u003cimg class=\"fr-fic fr-dii\" style=\"width: 400px; height: 40px;\" src=\"http:\/\/ftp3.syscom.mx\/usuarios\/yhermosillo\/SILENT%20KNIGHT\/Frenhyt.png\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eThe IFP-2100 (red) and IFP-2100B (black) are fire alarm\/addressable analog control panels (FACP). The basic IFP-2100 panel contains a built-in signaling line circuit (SLC). which supports 159 IDP\/SK sensors and 159 IDP\/SK modules or 127 devices using the SD protocol. Additional SLC loops can be added using the Model 6815 SLC Expander for System Sensor Devices (IDP\/SK) to increase total point capacity to 2100 points per panel; or the model 5815XL for Hochiki devices (SD) to increase point capacity to a maximum of 2032 points per panel.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eThe IFP-2100 has networking capability for up to 32 panels. The network has two modes of operation: multiple panels covering a large building\u0026amp;comma; or multiple independent buildings. The RFP-2100 (red) or RFP2100B (black) can be used in a networked system where at least one IFP2100 is on the system, It is the same as the IFP-2100 without the screen.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e The IFP-2100 has eight Flexput™ ICs that can be configured for auxiliary power, notification outputs\u0026amp;comma; input for NO dry contacts or for conventional smoke detector inputs (Class A or Class B). The FACP also has built-in communicators; Dual Telephone Line Digital Alarm Transmitter (DACT)\u0026amp;comma; IP communicator and a cellular communicator can be used optionally. Contains a form C trouble relay\u0026amp;comma; and two programmable Form C relays.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eThe IFP-2100 has powerful functions such as detector sensitivity, day\/night thresholds\u0026amp;comma; drift compensation\u0026amp;comma; pre-failure maintenance alert and calibration problem alert. The IFP-2100 supports a variety of devices, including RA2000 remote annunciators\u0026amp;comma; RA-1000 or RA-100\u0026amp;comma; 5824 parallel\/serial printer interface module RPS-1000 power module: and IDP devices\u0026amp;comma; SK or SD. \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"fr-fic fr-dii\" style=\"width: 360px; height: 342px;\" src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/IFP75B\/158605-farenhyt_addressablegroup_black_web.jpg\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/IFP2100B\/158611-diagrama_farenhyt.jpg\" alt=\"\" width=\"1144\" height=\"750\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/IFP2100B\/158611-conexion_en_red_fh.jpg\" alt=\"\" width=\"1161\" height=\"750\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"HONEYWELL FARENHYT SERIES","offers":[{"title":"Default Title","offer_id":44879616639221,"sku":"IFP-2100B","price":59705.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/IFP2100B-h.png?v=1722079889"},{"product_id":"bobina-de-cable-de-305-m-4-conductores-x-14-awg-de-cable-direct-burial-negro","title":"305m cable reel 4 conductor x 14 AWG black DIRECT BURIAL cable.","description":"\u003cp\u003e\u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003eThis Genesis® cable features 4 stranded 14 AWG copper conductors and a direct burial rating. Choose this cable for a dependable fire alarm system wiring solution.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003eSPECIFICATIONS\u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCable rating:\u003c\/strong\u003e outdoor\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eWire gauge (AWG):\u003c\/strong\u003e 14\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eNumber of strands:\u003c\/strong\u003e 19\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eNumber of drivers:\u003c\/strong\u003e 4\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eInsulation colors:\u003c\/strong\u003e black\u0026amp;comma; network\u0026amp;comma; green\u0026amp;comma; yellow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eRipcord:\u003c\/strong\u003e yes\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eNominal Outer Diameter:\u003c\/strong\u003e 9mm.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eDC Resistance (Max):\u003c\/strong\u003e 2.62 Ohms \/ 1000 ft. at 20 °C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eImpedance (Nominal):\u003c\/strong\u003e 89 Ohms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCable listing:\u003c\/strong\u003e FPL, CL2\u0026amp;comma; Sunlight resistant\u0026amp;comma; direct burial.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003eStranded cable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eConductor material:\u003c\/strong\u003e bare copper\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eConductor Insulation Material:\u003c\/strong\u003e SRPVC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eShielding:\u003c\/strong\u003e No\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eJacket Material:\u003c\/strong\u003e PVC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eRated Voltage (Max):\u003c\/strong\u003e 300 Volts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eCapacitance (Nominal):\u003c\/strong\u003e 17.1 pF\/ft.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: roboto\u0026amp;comma; sans-serif;\"\u003e\u003cstrong\u003eVelocity of Propagation:\u003c\/strong\u003e 67%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879622504693,"sku":"4154-1008","price":14713.11,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/41541008-h_3e6c1c54-5753-406e-8294-62079f13fb37.png?v=1722080076"},{"product_id":"expansor-de-lazo-vplex-proporciona-128-mah-adicionales","title":"Vplex loop expander provides additional 128 mAh","description":"\u003cp\u003eThe 4297 V-Plex Loop Isolator\/Extender Module offers a dual advantage for commercial applications. As an isolation module, The 4297 allows installers to select groups of zones in a loop. For example, fire and burglary zones can be grouped separately; essentially isolate one from the other. This isolation feature prevents failure in one loop that can compromise the integrity of any other loop. The 4297 module also gives installers the flexibility to expand the wiring capacity of the entire system\u0026amp;comma; approximately 1219.2 meters. at 2438.4 meters.\u0026amp;comma; Without the additional expense of additional modules or control panels.\u003cbr\u003e\u003cbr\u003e Isolate V-Plex main loop open and short circuit faults.\u003cbr\u003e Provides additional V-Plex loop current.\u003cbr\u003e V-Plex loop isolation between main and extended loop.\u003cbr\u003e fully supervised.\u003cbr\u003e DC independent entrance\u0026amp;comma; no V-Plex primary loop current consumption. \u003cbr\u003eMonitors direct current input.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879624765685,"sku":"4297","price":1656.74,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_be7ee738-87a7-4ef6-9f2a-683026f8f2cf.png?v=1789267978"},{"product_id":"bobina-de-152-metros-de-alambre-2x18-awg-resistente-al-fuego-color-rojo-tipo-fplr-cl2r-cul-ft4-para-sistemas-contra-incendio-o-sistemas-de-evacuacion","title":"Coil of 152 Meters of Wire \/ 2x18 AWG \/ Fire Resistant \/ Red Color \/ Type FPLR- CL2R - C(UL) -FT4 \/ For Fire Fighting Systems or Evacuation Systems","description":"\u003cp\u003e 18 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eApplications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Fire detection alarms\u003c\/li\u003e\n\u003cli\u003e Panels with conventional technology\u003c\/li\u003e\n\u003cli\u003e Panels with analog addressable technology\u003c\/li\u003e\n\u003cli\u003e Evacuation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Type: Cable (1 pair).\u003c\/li\u003e\n\u003cli\u003e Impedance (Ω): 75.\u003c\/li\u003e  \u003cli\u003eResistance in Ω at 100 m.: 2.13.\u003c\/li\u003e\n\u003cli\u003e Gauge: 18.\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Red.\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"line-height: 20.7999992370605px;\"\u003eOuter diameter (mm): 3.4\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 13:1424\u003c\/li\u003e\n\u003cli\u003e NEC 725 \u0026amp; 760.Outer diameter (mm): 3.7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eGuy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e FPLR= Limited power riser cables for fire alarms.\u003c\/li\u003e\n\u003cli\u003e CL2R= Class 2\u0026amp;comma; Limited power cables, riser remote control and signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e Operating temperature:\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e - 20°C to 75°C\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e Certifications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 1424\u003c\/li\u003e\n\u003cli\u003e NEC 760.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e* Price per reel of 152 meters\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879625060597,"sku":"4306-5504\/500","price":1263.79,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/43065504_500-h.png?v=1722080322"},{"product_id":"bobina-de-305-metros-de-alambre-2x18-awg-tipo-fplr-cl3r-ft4-color-rojo-resistente-a-la-intemperie-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 305 Meters of Wire \/ 2x18 AWG \/ Type FPLR-CL3R, FT4 \/ Red Color \/ Weather Resistant for Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e \u003cstrong style=\"line-height: 20.8px;\"\u003e18 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e\u003c\/strong\u003e \u003cbr\u003eSolid Soft Copper Conductors PVC Insulation identified by color code\u0026amp;comma; and total PVC lining.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"line-height: 20.8px;\"\u003eUse in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/span\u003e \u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eFire detection alarms.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eConventional technology panels.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eAddressable analog technology panels\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eEvacuation panels\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eOutdoor use\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eType: Cable (1 pair)\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eGauge: 18\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eInternal Color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eOuter diameter: 4.31mm\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eOperating temperature: -20°C to 75°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eType:\u003c\/strong\u003e \u003cspan style=\"font-weight: bold;\"\u003eFPLR = Limited power cables for Riser fire alarms\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; line-height: 107%; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eUL 1666 (Riser)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eCL3R\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt; line-height: 107%; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eCSA c22.2 No. 2556 (FT4).\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879625584885,"sku":"43061104\/1000","price":3211.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/430611041000-h.png?v=1722080330"},{"product_id":"bobina-de-305-metros-de-alambre-4x18-awg-tipo-fplr-cl2r-resistente-al-fuego-color-rojo-para-sistemas-contra-incendio-o-sistemas-de-evacuacion","title":"Coil of 305 Meters of Wire \/ 4x18 AWG \/ Type FPLR-CL2R \/ Fire Resistant \/ Red Color \/ For Fire Fighting Systems or Evacuation Systems","description":"\u003cp\u003e 18 GAUGE 4 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eApplications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Fire detection alarms\u003c\/li\u003e  \u003cli\u003ePanels with conventional technology\u003c\/li\u003e\n\u003cli\u003e Panels with analog addressable technology\u003c\/li\u003e\n\u003cli\u003e Evacuation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Use: Outdoor\u003c\/li\u003e\n\u003cli\u003e Type: Wire (2 pairs).\u003c\/li\u003e\n\u003cli\u003e Impedance (Ω): 75.\u003c\/li\u003e\n\u003cli\u003e Resistance in Ω at 100 m.: 2.13.\u003c\/li\u003e\n\u003cli\u003e Gauge: 18.\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Red.\u003c\/li\u003e\n\u003cli\u003e Outer diameter (mm): 4.41?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 13:1424\u003c\/li\u003e\n\u003cli\u003e NEC 725 \u0026amp; 760.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eGuy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e FPLR= Limited power riser cables for fire alarms.\u003c\/li\u003e\n\u003cli\u003e CL2R= Class 2\u0026amp;comma; Limited power cables, riser remote control and signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eOperating temperature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e - 20°C to 75°C\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 1424\u003c\/li\u003e\n\u003cli\u003e NEC 760.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e* Price per reel of 305 meters\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879625781493,"sku":"43071104\/1000","price":5525.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/43071104_1000-h_65bbc477-953e-4f73-bb4f-1fcc1766b804.png?v=1722080331"},{"product_id":"carrete-de-alambre-305-metros-2x16-awg-color-rojo-tipo-fplr-cl3r-c-ul-ft4-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Wire Reel 305 Meters \/ 2x16 AWG \/ Red Color \/ Type FPLR, CL3R, C (UL) FT4 \/ For Applications in Fire Detection Systems and Evacuation Systems.","description":"\u003cp\u003e\u003c\/p\u003e  \u003cp\u003eGenesis Series from \u003cstrong\u003eHONEYWELL\u003c\/strong\u003e offers a complete range of low voltage cables for security, alarm systems\u0026amp;comma; fire detection\u0026amp;comma; audio\u0026amp;comma; voceo\u0026amp;comma; data\u0026amp;comma; structured cabling.\u003cbr\u003e With high-tech and innovative equipment to satisfy the most rigorous quality standards.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Type: Wire (1 pair).\u003c\/li\u003e\n\u003cli\u003e Impedance (Ω): 68.\u003c\/li\u003e\n\u003cli\u003e Resistance in Ω at 305 m.: 4.1.\u003c\/li\u003e\n\u003cli\u003e Zip Cord: Yes\u003c\/li\u003e\n\u003cli\u003e Caliber: 16.\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Red.\u003c\/li\u003e\n\u003cli\u003e Outer diameter (mm): 4.11.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003cli\u003e RoHS\u003c\/li\u003e\n\u003cli\u003e FPLR\u003c\/li\u003e\n\u003cli\u003e CL3R\u003c\/li\u003e\n\u003cli\u003e Sunlight Resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eOperating temperature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e -20 to 75°C\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e* 305 meter coil.\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879625912565,"sku":"4311-1004\/1000","price":3866.94,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/43111004_1000-h_698f3f6c-9bd9-4a13-8cb7-814804224df6.png?v=1722080079"},{"product_id":"bobina-de-alambre-de-305-metros-2x14-awg-tipo-fplr-cl2-color-rojo-para-aplicaciones-en-paneles-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"305 Meter Wire Coil \/ 2x14 AWG \/ Type FPLR-CL2 \/ Red Color \/ For Applications in Fire Detection Panels and Evacuation Systems","description":"\u003cp\u003e \u003cstrong style=\"line-height: 18.9090900421143px;\"\u003e14 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e Fire detection alarms\u003c\/li\u003e\n\u003cli\u003e Panels with conventional technology\u003c\/li\u003e\n\u003cli\u003e Addressable analogue technology panels\u003c\/li\u003e  \u003cli\u003eEvacuation panels \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eType: Cable (1 pair)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e Gauge: 14 AWG.\u003c\/li\u003e\n\u003cli\u003e Impedance: 70 (Ω)\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Red\u0026amp;comma; Black\u003c\/li\u003e\n\u003cli\u003e Outside diameter: 0.200\"\u003c\/li\u003e\n\u003cli\u003e\n\n \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType:\u003c\/span\u003e \u003cspan style=\"font-size: 10.5pt; font-family: 'Helvetica'\u0026amp;comma;sans-serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eFPLR = Limited power cables for Riser fire alarms\u003c\/span\u003e\u003c\/span\u003e\n\n\u003c\/li\u003e\n\u003cli\u003e \u003cstrong\u003eOperating temperature: -20°C to 75°C\u003c\/strong\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards and certification:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e UL 13 \u0026amp; 1424.\u003c\/li\u003e\n\u003cli\u003e NEC 725 \u0026amp; 760\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879626371317,"sku":"43131004\/1000","price":7130.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/431310041000-h_452b65ea-070f-402b-86ab-5680f41057b9.png?v=1722080323"},{"product_id":"bobina-de-152-metros-de-alambre-2x18-awg-blindado-tipo-fplr-color-rojo-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 152 Meters of Wire \/ 2x18 AWG \/ SHIELDED \/ Type FPLR \/ Red Color \/ For Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e \u003cstrong\u003e18 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 18 AWG; Armored\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 36.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 3.75\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPLR\u003c\/strong\u003e =(Riser Cable): Fire retardant cable according to UL 1666\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 152 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879626502389,"sku":"44025504","price":1974.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44025504-h_fef943a8-23a8-438a-97ea-a6e457edabe2.png?v=1722080330"},{"product_id":"bobina-de-152-metros-de-alambre-4x18-awg-blindado-tipo-fplr-color-rojo-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 152 Meters of Wire \/ 4x18 AWG \/ SHIELDED \/ Type FPLR \/ Red Color \/ For Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e\u003cstrong\u003e18 GAUGE 4 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e4 x 18 AWG; Armored\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 41\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u0026amp;comma; Green\u0026amp;comma; Yellow\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 4.14\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPLR\u003c\/strong\u003e =(Riser Cable): Fire retardant cable according to UL 1666\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 152 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879626797301,"sku":"44035504","price":3042.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44035504-h_dedabcc2-cfb3-4317-81a9-893662684131.png?v=1722080328"},{"product_id":"bobina-de-152-metros-de-alambre-2x16-awg-blindado-tipo-fplr-color-rojo-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 152 Meters of Wire \/ 2x16 AWG \/ SHIELDED \/ Type FPLR \/ Red Color \/ For Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e \u003cstrong\u003e16 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003c\/strong\u003e \u003cbr\u003eSolid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems. \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 16 AWG; Armored\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 37.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 4.47\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPLR\u003c\/strong\u003e =(Riser Cable): Fire retardant cable according to UL 1666\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 152 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879626961141,"sku":"44065504","price":2718.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44065504-h_593660ff-9953-4d99-a9df-8d3ef1b7a74c.png?v=1722080330"},{"product_id":"bobina-de-152-metros-de-alambre-2x14-awg-blindado-tipo-fplr-color-rojo-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 152 Meters of Wire \/ 2x14 AWG \/ SHIELDED \/ Type FPLR \/ Red Color \/ For Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e \u003cstrong\u003e14 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003c\/strong\u003e \u003cbr\u003eSolid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems. \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with addressable analogue technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 14 AWG; Armored\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 33.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 5.20\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPLR\u003c\/strong\u003e =(Riser Cable): Fire retardant cable according to UL 1666\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 152 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879627321589,"sku":"44085004","price":4217.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44085004-h_e2b82bfd-0d09-4312-9fdd-6e5ae281c921.png?v=1722080330"},{"product_id":"carrete-de-alambre-de-305-metros-2x16-awg-tipo-fplr-cl2r-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-voceo","title":"305 Meter Wire Reel \/ 2x16 AWG \/ Type FPLR-CL2R \/ For Applications in Fire Detection Systems and Paging Systems","description":"\u003cp\u003e \u003cstrong style=\"line-height: 18.9091px;\"\u003e16 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e Evacuation panels\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003eFire detection alarms\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cstrong\u003eType: Wire (1 pair)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\n \u003cstrong\u003eImpedance: 43\u003c\/strong\u003e (Ω)\u003c\/li\u003e\n\u003cli\u003e Caliber: 16\u003c\/li\u003e\n\u003cli\u003e External color:Red\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Grid.\u003c\/li\u003e\n\u003cli\u003e Outer diameter: 4.3mm.\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eOperating temperature: -20°C to 75°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\n \u003cstrong\u003e\u003cstrong\u003e\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eGuy:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/strong\u003e\u003cul type=\"disc\"\u003e  \u003cli class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eFPLR= Limited power cables for RISER fire alarms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli class=\"MsoNormal\"\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eCL2R =Class 2\u0026amp;comma; Limited power cables, riser remote control and signaling.\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003eUL 13 \u0026amp;1424\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003eNEC 725 \u0026amp; 760\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e  \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879627387125,"sku":"4423-1004\/1000","price":3788.59,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44231004.jpg?v=1722080079"},{"product_id":"bobina-de-305-metros-de-alambre-4x16-awg-blindado-plenum-tipo-fplp-color-rojo-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 305 Meters of Wire \/ 4x16 AWG \/ SHIELDED Plenum \/ FPLP Type \/ Red Color \/ For Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e \u003cstrong\u003e16 GAUGE 4 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e4 x 16 AWG; Shielded Plenum\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 43\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u0026amp;comma; Green\u0026amp;comma; Yellow\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 5.23\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPLP\u003c\/strong\u003e =(Plenum Cable)\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e NFPA 262 (Plenum)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT6)\u003c\/li\u003e\n\u003cli\u003e RoHS Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44879627485429,"sku":"46071004","price":9559.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/46071004-h_3f0610e5-b283-47f5-af35-6039e1d6bb28.png?v=1722080331"},{"product_id":"comunicador-de-alarma-contra-incendios-de-4-canales-uso-paneles-firelite","title":"4 Channels Fire Alarm Communicator Use Firelite Panels","description":"\u003cp class=\"MsoNormal\"\u003eFire - Lite's Fire-Watch 411UDAC is a compact multi-faceted fire alarm communicator \u0026amp; comma; self-contained or slave \u0026amp; comma; designed for a variety of fire and fire-free applications. It provides four channels (inputs) that accept water flow devices \u0026amp; comma; two-and four-wire smoke detectors \u0026amp; comma; extraction stations \u0026amp; comma; and other normally open contact devices.\u003cbr\u003eThe 411UDAC is a cost-effective solution for applications that require an existing (or new) fire alarm control or safety panel to transmit system status to an off-site monitoring facility to meet the remote monitoring requirement. Due to its extremely flexible programming options \u0026amp; comma; the 411UDAC is also ideal. To use as an independent unit to monitor: sprinkler systems in water flow and monitoring conditions; (i. e. \u0026amp; comma; water level \u0026amp; comma; gas detection \u0026amp; comma; air flow loss); and the normally open contact devices.\u003c\/p\u003e \u003cp\u003eFeatures\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp class=\"MsoNormal\"\u003e\u0026bull; Four monitored monitoring channels (inputs): three fixed Style B (Class B) and one Style A (Class A) or Style B (Class B).\u003cbr\u003e\u0026bull; Entries can be individually programmed for stand-alone applications \u0026amp; comma; or when monitoring a control panel \u0026amp; comma; for:\u003c\/p\u003e \u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e \u003cul style=\"list-style-type: circle;\"\u003e \u003cli class=\"MsoNormal\"\u003eTwo and four-wire smoke detectors (inputs 1 and 3).\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eJalón station.\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eContacts N\/O.\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eControl panel problems (slave mode).\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eSupervisión.\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eSupervision (self-resetable).\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eWater flow (silenced).\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eWater flow (not silenced).\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eMonitoring of processes.\u003c\/li\u003e \u003cli class=\"MsoNormal\"\u003eProcess monitoring (self-resetable).\u003c\/li\u003e \u003c\/ul\u003e \u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e \u003cp class=\"MsoNormal\"\u003e\u0026bull; A \u0026ldquo;Y” (Class B) NAC (Bell) notification device.\u003cbr\u003e\u0026bull; 1.0 Amp notification device power.\u003cbr\u003e\u0026bull; (Temporary) coded notification device (bell \u0026amp; comma; signal) circuit.\u003cbr\u003e\u0026bull; 12 VDC operation.\u003cbr\u003e\u0026bull; Capable of 60 hours of waiting\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44948747944181,"sku":"411U-DAC","price":8246.82,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_a863c857-cbc9-479f-bbd7-f7093575c59e.png?v=1785292368"},{"product_id":"gabinete-para-dos-baterias-de-respaldo-de-55-ah-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-fas","title":"Cabinet for two 55 AH backup batteries. For applications in fire detection systems (FAS).","description":"\u003cp\u003eThis cabinet consists of a box with a locked door that articulates at the bottom to open down for access.\u003cbr\u003e It is designed to mount a minimum of 6 inches under the control panel of the fire alarm\u003cbr\u003e (FACP). \u003cbr\u003e This Cabinet must be mounted cleanly \u0026amp; comma; dry \u0026amp; comma; vibrations-free \u0026amp; comma; using the six holes provided.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e Cabinet for two backup batteries up to 55 Ah.\u003cbr\u003e Dimensions: 39.62 cm x 13.02 cm x 39.37 cm\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44948748173557,"sku":"BB55F","price":7524.28,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S1000_cc75248a-e22f-4d81-aa93-4d34fa281a8f.png?v=1785212772"},{"product_id":"certificacion-virtual-fire-lite","title":"Virtual Fire Lite Certification.","description":"\u003cdiv\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eHoneywell Fire Lite Certified Virtual Training.\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e \u003cdiv\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eAcademia Fire-Lite Serie Endurance\u003c\/span\u003e\u003c\/div\u003e \u003cdiv\u003e \u003c\/div\u003e \u003cdiv\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eWhen buying this kit, 2 people can be certified once the kit is paid, please send an email to\u003ca href=\"mailto:jonathan.medina@syscom.mx\"\u003eJonathan.medina@syscom.mx\u003c\/a\u003eAnd\u003ca href=\"mailto:manlio.velazquez@syscom.mx\"\u003eManlio.velazquez@syscom.mx\u003c\/a\u003eSince it is limited space.\u003c\/span\u003e\u003c\/div\u003e \u003cdiv\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThis certification consists of 2 weeks:\u003c\/span\u003e\u003c\/div\u003e \u003cul\u003e \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eWeek 1: When paying for the kit and sending the registration mail. The student will be registered on a Honeywell platform where they can watch pre-certification videos.\u003c\/span\u003e \u003c\/span\u003e\u003c\/li\u003e \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eWeek 2: When complying with the requirements automatically, the virtual \u0026amp; comma; certification of 3 days is passed.\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eYou practice live with use of the Gotomeeting platform!\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cstrong style=\"font-family: 'Times New Roman';\"\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eNOTE: \"THE KIT IS SUBJECT TO AVAILABILITY OF ITS COMPONENTS \u0026amp; comma; SO THE CONTENT MAY NOT INCLUDE ALL MODELS \u0026amp; comma; IN CASE THERE IS NO EXISTENCE OF ANNED MODEL AINCE THE KIT \u0026amp; comma; THE COMPONENTS WITH WHICH YOU DO NOT COUNT ON STOCK ARE NOT SUPPORTED\"\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e \u003cdiv\u003e\u003cimg src=\"https:\/\/ftp3.syscom.mx\/usuarios\/fotos\/EXPERTAFL\/187918-requerimientos.jpg\" alt=\"\" width=\"538\" height=\"300\"\u003e\u003c\/div\u003e \u003cp\u003e \u003c\/p\u003e \u003cul\u003e \u003cli\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eThe Fire-Lite Model EXPERTAFL Online Certification Kit includes:\u003c\/span\u003e\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e1 ES-50XI (subject to exchange for availability)\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e1 ANN80\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e2 SD365\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e2 BG-12LX\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003c\/span\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e2 P2RL * The siren\/strobe model may vary depending on availability\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e1 MDF-300\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e1 CMF-300\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e1 CRF-300\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003c\/span\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e2[[PL712]](subject to availability \u0026amp; comma; if there is no existence carry your own batteries or quote PS- 1270-F2 or PS-12120-F2)\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eRecommendation before the COVID-19.\u003c\/span\u003e \u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eSYSCOM recommends the use of mouth covers at all times and respect the measures established by the government such as isolation and healthy distance, this in order to prevent the risk of contagion.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e* Note: the kit may vary depending on the availability of the panels \u0026amp; comma; therefore the price may vary.\u003c\/span\u003e\u003c\/p\u003e \u003cp\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eIF YOU CAN'T COOTING KIT FOR SENDING MAIL TO JONATHAN.MEDINA@SYSCOM.MX\u003c\/span\u003e\u003c\/p\u003e","brand":"FIRE-LITE","offers":[{"title":"Default Title","offer_id":44948748468469,"sku":"EXPERTAFL","price":32048.78,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/EXPERTAFL-h_678aefda-0c3d-4582-9d62-8d7da53ebbaa.png?v=1722097020"},{"product_id":"cable-de-programacion-estandar-para-firenet-firenet-plus-0100-03220","title":"Standard Programming Cable for FireNET \u0026amp; FireNET PLUS (0100-03220)","description":"\u003cp\u003e 46191501\u003c\/p\u003e","brand":"HOCHIKI","offers":[{"title":"Default Title","offer_id":44952075567349,"sku":"A187","price":683.14,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/A187-h.png?v=1722105761"},{"product_id":"tarjeta-de-expansor-de-un-lazo-slc-para-paneles-serie-firenet-plus-0100-05920","title":"SLC Single Loop Expander Card for Firenet Plus Series Panels (0100-05920)","description":"\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003eSLC Single Loop Expander Card for Firenet Plus Series Panels (0100-05920) only.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003c\/p\u003e  \u003cp style=\"text-align: justify;\"\u003e\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif; font-size: 16px; background-color: #ffffff;\"\u003eThe \u003cstrong\u003eFNP-1127-SLC\u003c\/strong\u003e \u003cstrong\u003eSingle SLC Loop Expander\u003c\/strong\u003e is a single loop expander for the FireNET Plus FNP-1127E series control panel. The FNP-1127-SLC increases the loop capacity of the panel from 1 loop to 2 loops\u0026amp;comma; doubling the loop capacity from 254 analog addressable points to 508. The loop extender board installs quickly and mounts to the back of the main control panel. The FNP-1127-SLC has the same functionality as the SLC loop built into the FireNET Plus panel and uses Hochiki's \u003cstrong\u003erobust DCP loop protocol\u003c\/strong\u003e for highly reliable and fast alarm reporting. Shielded or twisted pair cable for the SLC loop is not necessary.\u003c\/span\u003e\u003c\/p\u003e  \u003cp\u003e\u003cspan style=\"font-size: 12pt; font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cspan style=\"background-color: #ffffff;\"\u003eProduct code:\u003c\/span\u003e \u003cstrong\u003e\u003cspan style=\"background-color: #ffffff; overflow-wrap: break-word !important;\"\u003e0100-05920\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif; font-size: 12pt;\"\u003e\u003cspan style=\"background-color: #ffffff;\"\u003eAdds an SLC loop to the FireNET Plus control panel (FNP-1127E series).\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cspan style=\"font-size: 12pt; background-color: #ffffff;\"\u003eThe SLC loop is capable of 127 sensors\/modules, plus 127 analog sound bases\u0026amp;comma;\u003c\/span\u003e \u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003efor a potential total of 254 addresses.\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif;\"\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003eThe FireNET Plus 1127E Control Panel supports one FNP-1127-SLC, for a total of\u003c\/span\u003e \u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003etwo SLC loops per panel.\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003cli\u003e\u003cp style=\"margin: 0px 0px 10px; font-size: 0.875rem; background-color: #ffffff; overflow-wrap: break-word !important;\"\u003e \u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003eSupports Class A and B wiring methods per NFPA 72 Styles 4\u0026amp;comma; 6 and 7\u003c\/span\u003e \u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003e(Style 7 requires insulators).\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif; overflow-wrap: break-word !important;\"\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003eFully supervised, power-limited SLC circuit.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; line-height: 17.12px; font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif; overflow-wrap: break-word !important;\"\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003eSupports Hochiki DCP (digital communication protocol).\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; line-height: 17.12px; font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif; overflow-wrap: break-word !important;\"\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003eSame functionality as the built-in loop in the FireNET Plus control panel.\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; font-family: arial\u0026amp;comma; helvetica\u0026amp;comma; sans-serif; overflow-wrap: break-word !important;\"\u003e\u003cspan style=\"font-size: 12pt; line-height: 17.12px; overflow-wrap: break-word !important;\"\u003eUses standard cable; shielded\/twisted pair is not necessary in SLC loops.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e","brand":"HOCHIKI","offers":[{"title":"Default Title","offer_id":44952075796725,"sku":"FNP-1127-SLC","price":6351.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/portada_0S400_a3ed9ff9-901a-491e-98a1-351a3278c6de.png?v=1786415510"},{"product_id":"bobina-de-305-metros-de-alambre-2x18-awg-color-rojo-tipo-fplr-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 305 Meters of 2x18 AWG Wire \/ Red Color \/ FPLR Type \/ For Applications in Fire Detection Systems and Evacuation Systems.","description":"\u003cp\u003e 18 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e \u003cbr\u003eSolid Soft Copper Conductors PVC Insulation identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eApplications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Fire detection alarms\u003c\/li\u003e\n\u003cli\u003e Panels with conventional technology\u003c\/li\u003e\n\u003cli\u003e Panels with addressable analogue technology\u003c\/li\u003e\n\u003cli\u003e Evacuation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Use: Indoor\u003c\/li\u003e\n\u003cli\u003e Type: Cable (1 pair).\u003c\/li\u003e\n\u003cli\u003e Impedance (Ω): 75.\u003c\/li\u003e\n\u003cli\u003e Resistance in Ω at 100 m.: 2.13.\u003c\/li\u003e\n\u003cli\u003e Gauge: 18.\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Red.\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"line-height: 20.7999992370605px;\"\u003eOuter diameter (mm): 3.4\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eGuy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e  \u003cli\u003eFPLR= Limited power riser cables for fire alarms.\u003c\/li\u003e\n\u003cli\u003e CL3R= Class 3\u0026amp;comma; Limited Power Cables and Intercom Wiring Applications: security\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e audio and background music.limited power\u0026amp;comma; riser remote control and signaling.\u003c\/p\u003e\n\u003cp\u003e Operating temperature:\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e - 20°C to 75°C\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e* Price per reel of 305 meters.\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":44952084611317,"sku":"44021104","price":4180.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44021104-h.png?v=1722106000"},{"product_id":"sirena-estrobo-para-pared-color-rojo-sin-etiquetas","title":"Red wall strobe siren, without labels","description":"\u003cp\u003e \u003cstrong\u003eSTROBE SPEAKERS\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eDuring an emergency, Building occupants and people in the facility need to quickly understand what is happening and what actions to take. L Series Strobe Speakers deliver clear, intelligible messages and visible notifications necessary for code compliance\u0026amp;comma; save lives and protect property. Also\u0026amp;comma; Strobe speakers with selectable output offer many features to reduce ground faults and simplify installation. Rotary switches allow installers to select voltage and power, and 7 field-selectable candela settings for wall and ceiling mounting fit any application. SP series low total harmonic distortion provides high fidelity and high sound output\u0026amp;comma; making them ideal for use in environments with a lot of ambient noise. Plug-in design and universal mounting plate provide additional flexibility. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Plug-in design and protective cover reduce ground faults\u003c\/li\u003e\n\u003cli\u003e Universal mounting plate with a built-in shorting spring that tests wiring continuity before installation\u003c\/li\u003e\n\u003cli\u003e No extension ring required\u003c\/li\u003e\n\u003cli\u003e Field selectable candela settings for wall units: 15\u0026amp;comma; 30\u0026amp;comma; 75\u0026amp;comma; 95\u0026amp;comma; 110\u0026amp;comma; 135 and 185\u003c\/li\u003e\n\u003cli\u003e Automatic selection of 12 or 24 V operation in 15 and 30 candles\u003c\/li\u003e\n\u003cli\u003e Rotary switch simplifies field selection of speaker voltage (25 and 70@7 Vrms) and power settings (1\/4@1\/2@1 and 2W)\u003c\/li\u003e\n\u003cli\u003e Speakers offer high fidelity and high sound output\u003c\/li\u003e\n\u003cli\u003e 520 Hz +\/- 10% square wave tone capability with compatible fire alarm control panel (FACP)\u003c\/li\u003e\n\u003cli\u003e Tamper resistant construction\u003c\/li\u003e\n\u003cli\u003e Updated modern aesthetic\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eGrades:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e *Simple device without markings\u003c\/p\u003e  \u003cp\u003e*Compatible with BZR trims BZRC\u0026amp;comma; BZSPR\u0026amp;comma; BZSPRC for red devices (white letters) and BZW\u0026amp;comma; BZWC\u0026amp;comma; BZSPW\u0026amp;comma; BZSPWC for white devices (red letters).\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":44952103190773,"sku":"SPSRLP","price":1824.82,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/SPSRLP-h.png?v=1722106336"},{"product_id":"bobina-de-305-metros-2-x-16-awg-enterrado-directo-fpl-para-intemperie","title":"Coil of 305 Meters 2 X 16 AWG Direct Buried FPL, for Outdoors","description":"\u003cp\u003e \u003cstrong\u003eCABLE FOR DIRECT BURYING WITH 2 CONDUCTORS 16 GAUGE WITH BLACK SHEATH APPLICATIONS IN ALARMS\u0026amp;comma; SECURITY SYSTEMS. AUTOMATION\u0026amp;comma; MULTIPURPOSE.\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eHoneywell Genesis Series direct burial cables are specially designed to be buried underground. Made with a more ribbed sheath\u0026amp;comma; These cables have a higher threshold of resistance to crushing and impact. Our outdoor cables\u0026amp;comma; They are not only designed to be buried\u0026amp;comma; but are also independently tested; also\u0026amp;comma; They are approved to meet direct burial and wet location requirements.\u003cbr\u003e\u003c\/strong\u003e \u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eTheft detection alarms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eSecurity systems\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eMultipurpose application\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 16 AWG\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Black\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 7.49\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPL\u003c\/strong\u003e =(Fire Power Limited) : General purpose cable in fire application\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e U.L.\u003c\/li\u003e\n\u003cli\u003e FPL\u0026amp;comma; CL2\u0026amp;comma; Buried Direct\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44952118853877,"sku":"4151-1008","price":6018.96,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/41511008-h_203ba9bf-6e08-4d41-9c99-c39041832260.png?v=1722106817"},{"product_id":"bobina-de-305-metros-cable-2-x-14-awg-tipo-fpl-color-negro-para-uso-en-intemperie-y-enterrado-directo-uso-en-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"305 meter coil \/ 2 x 14 AWG Cable \/ FPL type \/ Black Color \/ For outdoor use and direct burial \/ Use in applications in fire detection systems and Evacuation Systems.","description":"\u003cp\u003e \u003cstrong\u003eCable for direct burial\u003c\/strong\u003e\u003c\/p\u003e  \u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"font-size: 10.5pt; line-height: 107%; font-family: 'Arial'\u0026amp;comma;sans-serif;\"\u003eHoneywell Genesis® Series direct burial cables are specially designed to be buried underground. Made with a more ribbed sheath\u0026amp;comma; These cables have a higher threshold of resistance to crushing and impact. Our outdoor cables are not only designed to be buried\u0026amp;comma; but are also independently tested; also\u0026amp;comma; are approved by to meet direct burial and wet location requirements.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology.\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with addressable analogue technology.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels.\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 14 AWG\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Black\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 7,874\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPL\u003c\/strong\u003e = Fire Alarm Limited Power Cable.\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e U.L.\u003c\/li\u003e\n\u003cli\u003e CL2\u0026amp;comma; Direct Burial (direct burial) outdoors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44952118984949,"sku":"4153-1008","price":8638.35,"currency_code":"MXN","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/41531008-h_bb88e410-700e-4270-9f0e-2443dd287480.png?v=1722106819"},{"product_id":"bobina-de-305-m-2-x-18-awg-fpl-enterrado-directo-e-intemperie-para-incendio","title":"COIL OF 305 M 2 X 18 AWG FPL DIRECT BURIED AND OUTDOOR FOR FIRE","description":"\u003ch3 class=\"MsoNormal\"\u003e Cable for direct burial\u003c\/h3\u003e  \u003cp\u003e\u003cspan style=\"font-size: 10.5pt; line-height: 107%; font-family: 'Arial'\u0026amp;comma;sans-serif; color: #202124;\"\u003eHoneywell Genesis® Series direct burial cables are specially designed to be buried underground. Made with a more ribbed sheath\u0026amp;comma; These cables have a higher threshold of resistance to crushing and impact. Our outdoor cables are not only designed to be buried\u0026amp;comma; but are also independently tested; also\u0026amp;comma; are approved by to meet direct burial and wet location requirements.\u003c\/span\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 18 AWG\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 107\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Black\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 3.75\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPL\u003c\/strong\u003e = Limited Power Fire Alarm Cable.\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e U.L.\u003c\/li\u003e\n\u003cli\u003e CL2\u0026amp;comma; Direct Burial\u0026amp;comma; Sunlight Resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44952119083253,"sku":"41561008","price":6922.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/41561008-h_dc93a03f-8307-4c65-ba2e-7f16c7a5bbb5.png?v=1722106819"},{"product_id":"bobina-de-305-metros-de-alambre-2x16-awg-para-aplicaciones-de-incendio-fplr-uso-interior-blindado-solido-color-rojo","title":"Coil of 305 Meters of Wire \/ 2x16 AWG \/ For FPLR Fire Applications \/ INDOOR Use Armored Solid Red Color","description":"\u003cp\u003e 2 CONDUCTOR WIRE 16 GAUGE \u0026amp;comma; OAS WITH GENERAL SHIELDING WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation: identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eApplications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Indoor use\u003c\/li\u003e\n\u003cli\u003e Fire detection alarms\u003c\/li\u003e\n\u003cli\u003e Panels with conventional technology\u003c\/li\u003e\n\u003cli\u003e Panels with analog addressable technology\u003c\/li\u003e\n\u003cli\u003e Evacuation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Type: Cable (1 pair).\u003c\/li\u003e\n\u003cli\u003e Impedance (Ω): 30.\u003c\/li\u003e\n\u003cli\u003e Caliber: 16.\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Red. \u003c\/li\u003e\n\u003cli\u003eOuter diameter (mm): 1.66\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 13:1424\u003c\/li\u003e\n\u003cli\u003e NEC 760.\u003c\/li\u003e\n\u003cli\u003e UL 1685\u003c\/li\u003e\n\u003cli\u003e C (UL)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eGuy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e FPLP= Plenum limited power cables for fire alarms.\u003c\/li\u003e\n\u003cli\u003e CL2P= Class 2\u0026amp;comma; Limited power cables, plenum remote control and signaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eOperating temperature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e - 20°C to 75°C\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e* Price per reel.\u003cbr\u003e * 305 meter reel\u003c\/strong\u003e .\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44952119607541,"sku":"44061104","price":5257.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/44061104-h_f9e47baf-2cf2-4b7c-9c7c-1e57fe0415d7.png?v=1722106820"},{"product_id":"bobina-de-305-metros-de-alambre-2-x-14-awg-tipo-fplp-de-color-rojo-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 305 meters of 2 x 14 AWG wire, type FPLP, red, for applications in fire detection systems and Evacuation Systems.","description":"\u003cp\u003e \u003cstrong\u003e14 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; AND VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e\u003cbr\u003e Use in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/strong\u003e \u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003cul\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt; font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003eFire detection alarms\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with conventional technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt;\"\u003e\u003cspan style=\"font-family: 'Times New Roman'\u0026amp;comma; serif;\"\u003ePanels with analog addressable technology\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt; font-family: 'Times New Roman'\u0026amp;comma;serif; mso-fareast-font-family: 'Times New Roman'; mso-fareast-language: ES-MX;\"\u003e\u003cspan style=\"font-size: 12pt;\"\u003eEvacuation panels\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eType: \u003cstrong\u003e2 x 14 AWG\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eImpedance (Ω): 54.\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eExternal color: Red\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eInternal color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOuter diameter (mm): 4.62\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003e\u003cstrong\u003eFPLP\u003c\/strong\u003e = (PLENUM Cable): Flame retardant cable, and low emission of dense smoke\u0026amp;comma; toxic and corrosive according to ANSI\/NFPA 262\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 13.5pt;\"\u003e\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif; font-size: 12pt;\"\u003eOperating temperature: -20°C to 75°C\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cstrong\u003eStandards:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e UL 910\u003c\/li\u003e\n\u003cli\u003e CSA (FT6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e  \u003cp\u003e\u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":44952119902453,"sku":"45131004","price":9379.9,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/45131004-h_e099289a-43f6-4b93-9b44-d7a8d74388de.png?v=1722106822"},{"product_id":"bobina-de-305-metros-de-alambre-4x14-awg-tipo-fplr-cl3r-resistente-al-fuego-color-rojo-para-sistemas-contra-incendio-o-sistemas-de-evacuacion","title":"Coil of 305 Meters of Wire \/ 4x14 AWG \/ Type FPLR-CL3R \/ Fire Resistant \/ Red Color \/ For Fire Fighting Systems or Evacuation Systems ","description":"\u003cp\u003e\u003cimg src=\"http:\/\/ftp3.syscom.mx\/usuarios\/maguilar\/Icons\/RoHS%20Icon.png\" alt=\"\" width=\"59\" height=\"42\"\u003e\u003c\/p\u003e\n\u003cp\u003e 14 GAUGE 4 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation identified by color code\u0026amp;comma; and total PVC lining.\u003cbr\u003e \u003cbr\u003eUse in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eApplications :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Fire detection alarms\u003c\/li\u003e\n\u003cli\u003e Panels with conventional technology\u003c\/li\u003e\n\u003cli\u003e Panels with analog addressable technology\u003c\/li\u003e\n\u003cli\u003e Evacuation panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCharacteristics :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e Type: Wire (2 pairs).\u003c\/li\u003e\n\u003cli\u003e Impedance (Ω): 63.\u003c\/li\u003e\n\u003cli\u003e Resistance in Ω at 305 m.: 2.57\u003c\/li\u003e\n\u003cli\u003e Caliber: 14.\u003c\/li\u003e\n\u003cli\u003e External color: Red.\u003c\/li\u003e\n\u003cli\u003e Internal color: Black\u0026amp;comma; Red\u0026amp;comma; Green and yellow.\u003c\/li\u003e\n\u003cli\u003e Outer diameter (mm): 5.71\u003c\/li\u003e\n\u003cli\u003e FT4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e UL 1666 (Riser)\u003c\/li\u003e\n\u003cli\u003e CSA C22.2 No. 2556 (FT4)\u003c\/li\u003e\n\u003cli\u003e RoHS Compliant\u003c\/li\u003e\n\u003cli\u003e UL Listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003eGuy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e FPLR= Limited power riser cables for fire alarms.\u003c\/li\u003e\n\u003cli\u003e CL3R= Class 3\u0026amp;comma; Limited power cables, riser remote control and signaling.\u003c\/li\u003e\n\u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e - 20°C to 75°C\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e \u003cstrong\u003e* Price per reel of 305 meters\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":45021127573749,"sku":"4314-1004\/1000","price":12118.38,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/43141004_1000-h_a7b10a3f-ffac-4ca1-af37-96f6af6f795c.png?v=1722111964"},{"product_id":"bobina-de-305-metros-de-alambre-2x18-awg-tipo-fplp-cl3p-ft6-color-rojo-resistente-a-la-intemperie-para-aplicaciones-en-sistemas-de-deteccion-de-incendio-y-sistemas-de-evacuacion","title":"Coil of 305 Meters of Wire \/ 2x18 AWG \/ Type FPLP-CL3P, FT6 \/ Red Color \/ Weather Resistant for Applications in Fire Detection Systems and Evacuation Systems","description":"\u003cp\u003e \u003cstrong style=\"line-height: 20.8px;\"\u003e\u003cimg src=\"http:\/\/ftp3.syscom.mx\/usuarios\/maguilar\/Icons\/RoHS%20Icon.png\" alt=\"\" width=\"59\" height=\"42\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cstrong style=\"line-height: 20.8px;\"\u003e18 GAUGE 2 CONDUCTOR WIRE WITH RED LINING APPLICATIONS IN FIRE DETECTION ALARMS\u0026amp;comma; VOICE SYSTEMS.\u003cbr\u003e\u003cbr\u003e Solid Soft Copper Conductors PVC Insulation identified by color code\u0026amp;comma; and total PVC lining.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cp\u003e \u003cspan style=\"line-height: 20.8px;\"\u003eUse in alarm applications with conventional technologies and analog addressable sensor wiring\u0026amp;comma; siren wiring\u0026amp;comma; wiring of detectors with addressable analogue technology\u0026amp;comma; audio evacuation systems.\u003c\/span\u003e \u003c\/p\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e \n\u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eCharacteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eFire detection alarms.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eConventional technology panels.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eAddressable analog technology panels\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eEvacuation panels\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003ePhysical and electrical characteristics:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eOutdoor use\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eType: Cable (1 pair)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eGauge: 18\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eExternal color: Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eInternal Color: Black\u0026amp;comma; Red\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eOuter diameter: 3.45mm\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eOperating temperature: -20°C to 75°C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e  \u003cli\u003e\n\u003cspan style=\"font-size: 12pt; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eType:\u003c\/strong\u003e \u003cspan style=\"font-weight: bold;\"\u003eFPLP = Limited power cables for Plenum fire alarms\u003c\/span\u003e\u003c\/span\u003e \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-sm-4\"\u003e\u003cdiv style=\"border-left: 5px solid #F52207; border-radius: 5px; padding: 5px; box-shadow: 2px 2px 10px #d8d8d8; -webkit-box-shadow: 2px 2px 10px #d8d8d8;\"\u003e\n\n \u003cspan style=\"font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; line-height: 107%; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eNFPA 262 (Plenum)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-family: times new roman\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eRoHS\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e \u003cspan style=\"font-size: 12pt; line-height: 107%; font-family: 'times new roman'\u0026amp;comma; times\u0026amp;comma; serif;\"\u003eCSA c22.2 No. 2556 (FT6).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003cstrong\u003e\u003cspan style=\"line-height: 20.8px;\"\u003e* Price per coil of 305 meters\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"HONEYWELL HOME RESIDEO","offers":[{"title":"Default Title","offer_id":45021127639285,"sku":"4506-1004\/1000","price":3112.88,"currency_code":"MXN","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/6522\/5205\/files\/45061004_1000-h_17273be5-96ab-4510-b6b3-85f4d6ebf624.png?v=1722111953"}],"url":"https:\/\/prolink.mx\/en\/collections\/todo.oembed?page=3","provider":"ProLink","version":"1.0","type":"link"}